EasyManua.ls Logo

Procom ML150HPA - User Manual

Procom ML150HPA
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
VENT-FREE PROPANE/LP
GAS SPACE HEATER
OWNER’S OPERATION AND
INSTALLATION MANUAL
INFRARED MODELS
ML150HPA, ML150TPA
ML250HPA, ML250TPA
Questions, problems, missing parts? Before returning to your retailer, call
our customer service department at 1-866-573-0674, 8:00 am - 4:30 pm CST,
Monday through Friday or email customerservice@usaprocom.com
WARNING: If the information in this manual is not
followed exactly, a re or explosion may result causing
property damage, personal injury or loss of life.
Do not store or use gasoline or other ammable va-
pors and liquids in the vicinity of this or any other
appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
Immediately call your gas supplier from a neighbors
phone. Follow the gas suppliers instructions.
If you cannot reach your gas supplier, call the re
department.
Installation and service must be performed by a quali-
ed installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.

Questions and Answers

  • T
    Travis EstesAug 17, 2025
    What to do if burner(s) does not light after ODS/pilot is lit in Procom Gas Heater?
    • J
      Justin MorrowAug 18, 2025
      If the burner(s) on your Procom Gas Heater do not light after the ODS/pilot is lit, the burner orifice may be clogged, so try cleaning it or replacing it. The burner orifice diameter may also be too small, in which case you should replace the burner orifice. It's also possible that the inlet gas pressure is too low, so contact your local gas supplier.
  • N
    Nichole RamosAug 20, 2025
    What to do if there is no spark at ODS/pilot when ignitor button is pressed in Procom ML150HPA Gas Heater?
    • T
      Thomas NguyenAug 20, 2025
      If the ignitor button is pressed, but there's no spark at the ODS/pilot on your Procom Gas Heater, several issues could be the cause. The ignitor electrode might be positioned incorrectly or broken, in which case you should replace the pilot assembly. It's also possible that the ignitor electrode isn't connected to the ignitor cable, suggesting the cable needs replacement. A pinched or wet ignitor cable can also prevent a spark; free the cable from any obstructions and keep it dry. If the ignitor cable is broken, replace it. Lastly, a bad piezo ignitor will also prevent a spark, so consider replacing it.
  • R
    Rachel TuckerAug 22, 2025
    Why does the flame go out when control knob is released on Procom ML150HPA Gas Heater?
    • B
      Billy BurkeAug 22, 2025
      If your Procom Gas Heater's ODS/pilot lights, but the flame goes out when you release the control knob, make sure the control knob is fully pressed in and held for at least 30 seconds after the pilot lights. Ensure the equipment shutoff valve is completely open. If these steps don't work, check the thermocouple connection at the control valve and hand tighten it until it is snug, plus an additional 1/4 turn. The pilot flame might not be touching the thermocouple due to low gas pressure or a dirty/partially clogged ODS/pilot. In this case, contact your local gas company or clean/replace the ODS/pilot. If the thermocouple or control valve is damaged, replace them.
  • A
    andersondanielAug 26, 2025
    Why there is gas odor even when control knob is in OFF position in Procom ML150HPA?
    • J
      jbrownAug 26, 2025
      If you smell gas when your Procom Gas Heater's control knob is in the OFF position, there may be a gas leak or a defective control valve. Locate and correct any gas leaks. If there are no apparent leaks, consider replacing the control valve.
  • T
    thomasderekAug 27, 2025
    Why is there gas odor during combustion in Procom Gas Heater?
    • T
      Teresa LoganAug 27, 2025
      If you smell gas during combustion with your Procom Gas Heater, there may be foreign matter between the control valve and burner. Take apart the gas tubing and remove any foreign matter. Also, check for gas leaks and correct them.
  • C
    Clayton HarrisAug 30, 2025
    What to do if there is a spark but no ignition in Procom Gas Heater?
    • D
      Dana PhillipsAug 30, 2025
      If the ignitor button is pressed and there is a spark at the ODS/pilot, but no ignition occurs in your Procom Gas Heater, first ensure the gas supply is turned on and the equipment shutoff valve is open. Confirm the control knob is fully pressed in while pressing the ignitor button and is in the PILOT position. If there's air in the gas lines from a recent installation, continue holding down the control knob and repeat the igniting operation until the air is removed. A clogged ODS/pilot can also prevent ignition; clean or replace the ODS/pilot assembly. Check the inlet gas pressure or replace the inlet gas regulator if the pressure is incorrect or the regulator is damaged. Finally, if using propane, check for a depleted gas supply and contact your local propane company if necessary.
  • S
    Samantha PierceSep 1, 2025
    Why does Procom ML150HPA shut off in use (ODS operates)?
    • B
      Brian RodriguezSep 1, 2025
      If your Procom Gas Heater shuts off while in use and the ODS (Oxygen Depletion Sensor) operates, it could be due to insufficient fresh air. Try opening a window or door for ventilation. Low line pressure may also cause this issue, so contact your local gas supplier. A partially clogged ODS/pilot might also be the cause; consider cleaning the ODS/pilot.
  • G
    Gerald MyersSep 4, 2025
    Why is there delayed ignition of burner(s) in Procom ML150HPA?
    • W
      wilsonrobertSep 4, 2025
      If the burner(s) on your Procom Gas Heater experiences delayed ignition, it could be due to low manifold pressure, so contact your local gas supplier. Alternatively, the burner orifice might be clogged, so clean or replace it.
  • Z
    zhughesSep 7, 2025
    What causes burner backfiring during combustion in Procom ML150HPA Gas Heater?
    • R
      Raymond FreemanSep 7, 2025
      If your Procom Gas Heater's burner is backfiring during combustion, the burner orifice may be clogged or damaged, so try cleaning or replacing it. The burner itself could also be damaged, requiring replacement. A damaged gas regulator may also be the cause, so consider replacing it.
  • C
    Christopher ReedSep 9, 2025
    Why burner plaque(s) does not glow in Procom ML150HPA Gas Heater?
    • K
      Kara BrockSep 9, 2025
      If the burner plaque(s) on your Procom Gas Heater does not glow, the plaque might be damaged, requiring you to replace the burner. Low inlet gas pressure could also be the reason, so contact your local gas company. Also, make sure the control knob is set to a locked position and not in between settings.

Procom ML150HPA Specifications

General IconGeneral
Heating Capacity150, 000 BTU
Ignition TypePiezo Ignition
ThermostatYes
VentingVent-Free
Fuel TypePropane
Heating AreaUp to 3, 750 sq ft