EasyManua.ls Logo

Procom MN060HBA - User Manual

Procom MN060HBA
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
VENT-FREE NATURAL GAS
SPACE HEATER
OWNER’S OPERATION AND
INSTALLATION MANUAL
INFRARED MODELS
MN060HBA, MN100HBA
MN100TBA
Questions, problems, missing parts? Before returning to your retailer, call
our customer service department at 1-866-573-0674, 8:00 am - 4:30 pm CST,
Monday through Friday or email customerservice@usaprocom.com
WARNING: If the information in this manual is not
followed exactly, a re or explosion may result causing
property damage, personal injury or loss of life.
Do not store or use gasoline or other ammable va-
pors and liquids in the vicinity of this or any other
appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
Immediately call your gas supplier from a neighbors
phone. Follow the gas suppliers instructions.
If you cannot reach your gas supplier, call the re
department.
Installation and service must be performed by a quali-
ed installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.

Questions and Answers

  • A
    Andrea McneilAug 18, 2025
    How to stop unwanted odors from my Procom Heater?
    • C
      Chris StoneAug 18, 2025
      To address unwanted odors from your Procom Heater, ventilate the room and stop using odor-causing products while the heater is running. Locate and correct any gas leaks. If you have a propane/LP model, refill the supply tank.
  • P
    Paul AvilaAug 20, 2025
    What to do if the Procom Heater pilot light goes out when I release the knob?
    • Z
      Zachary RobinsonAug 20, 2025
      If the ODS/pilot lights but the flame goes out when you release the control knob on your Procom Heater, ensure the control knob is fully pressed in. After the pilot lights, hold the knob for 30 seconds. Also, fully open the equipment shutoff valve and hand-tighten gas connections until snug, then tighten a quarter turn more. If these steps don't work, low gas pressure or a dirty pilot may be the cause. Contact your local gas company or clean the ODS/pilot, or replace the ODS/pilot assembly. If the issue persists, the thermocouple or control valve might need replacement.
  • L
    Linda HoweAug 23, 2025
    Why won't the burner light on my Procom Heater after the pilot is lit?
    • M
      Mr. Zachary ZimmermanAug 23, 2025
      If your Procom Heater burner(s) does not light after the ODS/pilot is lit, try cleaning the burner orifice or replacing it. If that doesn't solve the issue, contact your local gas supplier for assistance.
  • J
    jeremygonzalezAug 26, 2025
    Why does my Procom Heater smell like gas even when it's off?
    • R
      Richard AndersonAug 26, 2025
      If you notice a gas odor from your Procom Heater even when the control knob is in the OFF position, immediately locate and correct any gas leaks. If the odor persists, the control valve may need to be replaced.
  • H
    hallchristopherAug 27, 2025
    Why does my Procom Heater keep shutting off?
    • R
      rhondagibbsAug 28, 2025
      If your Procom Heater shuts off while in use, and the ODS (Oxygen Depletion Sensor) is operating, try opening a window or door to increase ventilation. If the problem continues, contact your local gas supplier or clean the ODS/pilot.
  • J
    Jessica LangAug 30, 2025
    How to fix a Procom Heater when the ignitor button produces no spark?
    • C
      Christopher WatsonAug 30, 2025
      If the ignitor button on your Procom Heater is pressed and there is no spark at the ODS/pilot, you can try replacing the pilot assembly, ignitor cable, or piezo ignitor. Also, ensure the ignitor cable is not pinched and is kept dry.
  • B
    Brandi HernandezSep 1, 2025
    What to do if Procom Heater sparks but doesn't ignite?
    • M
      Michelle MillerSep 1, 2025
      If you press the ignitor button on your Procom Heater and there's a spark at the ODS/pilot but no ignition, first, ensure the gas supply is on and the equipment shutoff valve is open. Fully press in the control knob while pressing the ignitor button and continue holding it down to remove air from the line. Clean the ODS/pilot or replace the ODS/pilot assembly. Check the inlet gas pressure or replace the inlet gas regulator. Finally, ensure the control knob is in the PILOT position.
  • B
    Brittany DiazSep 3, 2025
    Why is my Procom Heater burner backfiring?
    • A
      Allison JonesSep 4, 2025
      If the burner is backfiring during combustion in your Procom Heater, clean the burner orifice or replace it. If the problem persists, consider replacing the burner or gas regulator.
  • D
    Danielle PowellSep 6, 2025
    Why does my Procom Heater have a high yellow flame?
    • A
      Ann CastilloSep 6, 2025
      If your Procom Heater has a high yellow flame during burner combustion, check the burner for dirt and debris and clean it. If the issue continues, replace the gas regulator or contact your local gas supplier.
  • M
    Melissa MoonSep 8, 2025
    Why do I smell gas when my Procom Heater is on?
    • K
      kimberlyrodriguezSep 8, 2025
      If you notice a gas odor during combustion with your Procom Heater, disassemble the gas tubing and remove any foreign matter. Then, locate and fix any gas leaks.