EasyManua.ls Logo

Procom MD2TPA - User Manual

Procom MD2TPA
35 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
CAUTION - FOR YOUR SAFETY
Vent-Free Gas Wall Heater
Infrared
WARNING:This appliance is
equipped for (Natural and Propane)
gas. Field conversion is not permitted
other than between natural or
propane gases.
PC-MD2TPA-1202
Model # MD2TPA
MD3TPA
MD5TPA
MD3TPA-BB
MD5TPA-BB
This appliance may be installed in an aftermarket, permanently located, manufactured
(mobile) home, where not prohibited by local codes. This appliance is only for use with
propane or natural gas. This appliance is equipped with a simple means to switch
between propane and natural gas. Field conversion by any other means including the
use of a kit is not permitted.
This is an unvented gas-red heater. It uses air (oxygen) from the room in which it is
installed. Provisions for adequate combustion and ventilation air must be provided.
Refer to Air For Combustion and Ventilation section on page 8 of this manual.
INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual
for future reference.
Questions about installation, operation, or troubleshooting? Before returning to your retailer, contact our
customer service department at 1-877-886-5989, 8:00 a.m.- 4:30p.m., EST, Monday-Friday or e-mail
customerservice@usaprocom.com.
WARNING: IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED
EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY
DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE.
– Do not store or use gasoline or other ammable vapors and liquids in vicinity of
this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbors phone. Follow the gas
suppliers instructions.
If you cannot reach your gas supplier, call the re department.
– Installation and service must be performed by a qualied installer, service agency
or the gas supplier.
Español p. 36

Questions and Answers

  • J
    Jennifer LewisAug 18, 2025
    What to do if my Procom MD2TPA smells like gas even when it's off?
    • Y
      ystevensAug 18, 2025
      If you notice a gas odor when the control knob is in the OFF position, it could indicate a gas leak. You should locate and correct all leaks.
  • V
    vhenryAug 20, 2025
    Why does my Procom Gas Heater shut off while in use?
    • O
      oneillbrandonAug 20, 2025
      If your heater shuts off during use, it may be due to ventilation issues. Try opening a window or door to improve ventilation. You can also try to clean ODS/pilot.
  • J
    Jeffery TravisAug 23, 2025
    Why is there a high yellow flame during burner combustion in my Procom MD2TPA Gas Heater?
    • E
      Eric GomezAug 23, 2025
      A high yellow flame during burner combustion indicates that there is not enough air. Check the burner for dirt and debris, and clean the burner if necessary.
  • N
    Norman BlakeAug 26, 2025
    What to do if my Procom MD2TPA Gas Heater has no spark at the pilot?
    • J
      Joseph AtkinsonAug 26, 2025
      If there's no spark at the ODS/pilot when you press the ignitor button, you can try the following: replace the electrode, replace the ignitor cable, free the ignitor cable if it is pinched by metal or tubing, keep the ignitor cable dry, or replace the piezo ignitor.
  • N
    Norma LiuAug 27, 2025
    What to do if the Procom MD2TPA burner backfires during combustion?
    • J
      Jason PetersAug 28, 2025
      If the burner backfires during combustion, clean the burner orifice or replace the gas regulator.
  • J
    Joseph KennedyAug 30, 2025
    Why does my Procom MD2TPA have a gas odor during combustion?
    • T
      Tyler BryantAug 30, 2025
      If you notice a gas odor during combustion, disassemble the gas tubing and remove any foreign matter. Also, locate and correct all leaks.
  • I
    Ian HernandezSep 2, 2025
    Why does the pilot light go out when I release the control knob on my Procom MD2TPA?
    • J
      Joseph BradfordSep 2, 2025
      If the ODS/pilot lights but the flame goes out when the control knob is released, make sure to fully press in the control knob and keep it pressed for 30 seconds after the pilot lights. Also, ensure the equipment shutoff valve is fully open and hand tighten gas connections until snug, then tighten ¼ turn more. You may also need to replace the thermocouple.
  • S
    stevenswilliamSep 4, 2025
    How to fix a Procom Gas Heater that produces a whistling noise?
    • A
      Angela JohnsonSep 4, 2025
      To address a whistling noise, turn the control knob to the low (1) position and let the heater warm up for a minute. Operate the burner until air is removed from the line.
  • R
    Ronald BrennanSep 6, 2025
    Why does my Procom MD2TPA produce unwanted odors?
    • M
      mcooperSep 6, 2025
      The heater might be burning vapors from paint, hair spray, glues, etc. Ventilate the room and stop using odor-causing products while the heater is running. Also, locate and correct any gas leaks and refill the supply tank if you are using Propane /LP models.
  • S
    Sheila BarkerSep 9, 2025
    What to do if there is a spark but no ignition on my Procom MD2TPA Gas Heater?
    • D
      Denise ChristensenSep 9, 2025
      If there is a spark at the ODS/pilot but no ignition, make sure the gas supply is turned on and the equipment shutoff valve is open. Fully press in the control knob while pressing the ignitor button, and continue holding it down to remove air. You can also try cleaning the ODS/pilot, replacing the gas regulator, or turning the control knob to the PILOT position.