Peristaltic metering pump
DULCO flex Control, DFXa
Operating instructions
EN
Original operating instructions (2006/42/EC)Part no. 981953 BA DX 027 07/19 EN
Please carefully read these operating instructions before use. · Do not discard.
The operator shall be liable for any damage caused by installation or operating errors.
The latest version of the operating instructions are available on our homepage.

Table of Contents

Other manuals for ProMinent DFXa

Questions and Answers

  • R
    Richard BaileyAug 11, 2025
    What to do if ProMinent Water Pump shows Bus status STARTUP?
    • S
      Sarah HarperAug 11, 2025
      If your ProMinent Water Pump displays a 'Bus status STARTUP' message, wait briefly. Alternatively, configure the pump for active bus operation. Refer to the "Set-up" chapter for guidance.
  • C
    charlesduranAug 22, 2025
    What to do if ProMinent Water Pump shows Bus status PRE-OPERATIONAL?
    • S
      Stephen GonzalezAug 22, 2025
      If your ProMinent Water Pump displays a 'Bus status PRE-OPERATIONAL' message, wait briefly or initiate the pump via the bus.
  • C
    Carol MatthewsAug 31, 2025
    What to do if ProMinent Water Pump shows Bus status INIT?
    • V
      Vanessa CarterAug 31, 2025
      If your ProMinent Water Pump displays a 'Bus status INIT' message, wait briefly.

ProMinent DFXa Specifications

General IconGeneral
Dosing Accuracy±1%
Power Supply100-230 V AC, 50/60 Hz
Protection classIP 65
TypeDiaphragm pump
Stroke frequencyUp to 180 strokes/min
Suction Lift2 m water column
MaterialsPVDF, PTFE, EPDM
ControlManual or external control