Control elements and key functions
1
2
3
16
4
9
10
8
5
6
7
15 14 13 12 11
Control elements: overview
1 Operating light (green)
2 Warning light (yellow)
3 Error warning light (red)
4 Stroke length adjuster
5 LCD display
6 UP key
7 DOWN key
8 P key
9 STOP/START key
10 i key
11 Relay output (optional)
12 Metering monitor socket
13 External control socket
14 Float switch socket
15 Diaphragm rupture indicator socket
16 Mains switch
Key functions
In continuous display mode In settings mode
(operating) (settings)
STOP/START key
STOP
STOP
START
Press briefly Stop pump, Stop pump,
start pump start pump
P key
P
Press briefly Start batch (in “batch” operating mode only), Confirm entry- jump to next menu
Cancel error option or continuous display
Press for 2 s Change to settings mode ---
Press for 3 s --- Jump to continuous display
Press for 10 s Software version displayed
Press for 15 s Load factory settings (calibration) ---
i key
i
Press x1 Toggle between continuous displays Toggle between “change individual digits”
and change a figure"
Press x2 --- For “change individual digits”:
jumps to first digit
Arrow keys UP and DOWN
Press separately Change directly alterable values Select other settings,
(until “Set” appears) change individual digit or figure
Press simultaneously Prime (in “Stroke rate” permanent display)- ---

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ProMinent Sigma/ 1 S1Ba and is the answer not in the manual?

ProMinent Sigma/ 1 S1Ba Specifications

General IconGeneral
BrandProMinent
ModelSigma/ 1 S1Ba
CategoryWater Pump
LanguageEnglish

Related product manuals