Features of the S1Ca metering pumps
5 Features of the S1Ca metering pumps
5.1 Function description, motors
The pump has an integrated electronic overload cut-out in all versions. This responds as soon as
the maximum admissible power consumption is reached and stops the motor.
왘 If the motor stops due to a system overload the electronic controller detects the
fault and transmits a message which is displayed on the display panel and at the
pump.
왘 The fault signal can be cancelled by pressing the „P“ key, altering the level for a
brief period at the pause input (switch function) or by reconnecting the pump to the
mains.
NOTICE
If the pump has been switched off by the thermal overload protection, check that
it is not permanently overloaded.
IMPORTANT
• S1Ca-Pump types - in general 60 Hz performance data applies (because 60 Hz
internal operation).
• The controller changes over to stop-and-go mode at low stroke frequencies! This
takes place at stroke frequencies below 1/3 of the maximum stroke frequency. This
function is designed to ensure sufficient cooling of the motor and low stroke
frequencies.
S1Ca
Type: 100 – 230 V ± 10 %, 50/60 Hz
bei 100 V bei 230 V
Nominal output 130 W 130 W
Nominal current 2.2 1.2 A
Peak current (in operation) 3 A 3 A
Making peak current 8 A 16 A
Fuse, internal* 3.15 AT (1.5kA) 3.15 AT (1.5kA)
* Only genuine fuses of ProMinent, item no. 732414, may be used!