19
Diagrams for adjusting the capacity
p [bar]
S [%]
C [l/h]
C [l/h]
S2Cb
A
B
0
50
100
150
200
250
300
350
400
450
0 2 4 6
04350
07220
07120
16130
16090
16050
161412108
0
50
100
150
200
250
300
350
400
450
806040200 100 120
04350
07220
07120
16130
16090
16050
Fig. 41: A) Capacity C at minimum back pressure dependent on the stroke length s. B) Capacity C dependent on the
back pressure p.
Diagrams for adjusting the capacity
91