Diaphragm Motor-Driven Metering Pump
Sigma / 3 Basic Type S3Ba
Operating instructions
P_SI_0075_SW
Original operating instructions (2006/42/EC)Part no. 985905 BA SI 064 01/14 EN
Please carefully read these operating instructions before use! · Do not discard!
The operator shall be liable for any damage caused by installation or operating errors!
Technical changes reserved.

Questions and Answers

  • G
    gatessarahJul 27, 2025
    Why ProMinent Water Pump does not reach high pressure rates?
    • M
      Marissa EstradaJul 28, 2025
      There are several potential causes: 1. The valves may be dirty or worn. 2. The motor could be wired incorrectly; in this case, check the mains voltage and frequency, and ensure the motor is wired correctly. 3. The mains voltage might have failed; if so, eliminate the cause of the failure.
  • S
    Sandra DelgadoAug 2, 2025
    What to do if ProMinent Sigma/3 Basic S3Ba does not prime?
    • R
      Robin WilsonAug 2, 2025
      If your ProMinent Water Pump isn't priming despite full stroke motion and bleeding, consider these possibilities: * The valves may be dirty or worn. * The feed chemical might contain particles larger than 0.3 mm. If this is the case, install a suitable filter in the suction line.
  • S
    Stephen JohnsonAug 8, 2025
    What to do if ProMinent Sigma/3 Basic S3Ba has fluid escaping from the back plate?
    • J
      jwilliamsAug 8, 2025
      If fluid is escaping from the back plate of your ProMinent Water Pump, it could be due to: * The dosing head screws not being tight enough. Tighten the screws crosswise to the specified tightening torque. * A leaking diaphragm.
  • L
    Lindsey BrownAug 14, 2025
    Why ProMinent Sigma/3 Basic S3Ba Water Pump drive motor is very hot?
    • C
      Cheryl JonesAug 14, 2025
      If the drive motor of your ProMinent Water Pump is very hot, the discharge line is likely seriously constricted. Rectify any constriction of the discharge line.
  • A
    Alicia CampbellAug 21, 2025
    What to do if large leaks occur at the relief valve of ProMinent Sigma/3 Basic S3Ba?
    • D
      David ConleyAug 21, 2025
      If large leaks are occurring at the relief valve of your ProMinent Water Pump, the ball or ball seat may be dirty or worn. Clean or replace the ball and ball seat.

Summary

Safety Chapter

Safety Information Presentation

Details safety notes, signal words, and warning signs for hazard communication.

Functional Description

Hydraulic Installation

EX Area Hydraulic Safety

Safety precautions for installing in areas at risk from explosion.

Flammable Media Handling

Safety measures for installing with combustible feed chemicals.

Electrical Installation

EX Area Electrical Safety

Electrical installation safety requirements for hazardous locations.

Preventing Electric Shock Hazards

General electrical safety warnings and procedures to prevent shock.

Start Up

Pre-Startup Safety and Checks

Critical safety checks and procedures before and during initial pump startup.

Maintenance

General Maintenance Safety

Essential safety precautions to be observed during all maintenance tasks.

Repairs

Troubleshooting

Safety During Troubleshooting

Safety precautions and warnings to be followed when troubleshooting.

Common Faults and Solutions

Lists common pump faults, their causes, remedies, and responsible personnel.

ProMinent Sigma/3 Basic S3Ba Series Specifications

General IconGeneral
BrandProMinent
ModelSigma/3 Basic S3Ba Series
CategoryWater Pump
LanguageEnglish