Type Minimum pump capacity at maximum back pres‐
sure
Maximum
stroke
rate
Suction lift Permissible
priming
pressure,
suction side
Connector
size
bar psi l/h gph Strokes/
min
m WS bar R"-DN
120145 PVT 10 145 174 45 86 5 2 1 1/2" -
DN25
120145 SST 12 174 174 45 86 5 2 1 1/2" -
DN25
120190 PVT 10 145 251 66.2 124 5 2 1 1/2" -
DN25
120190 SST 12 174 251 66.2 124 5 2 1 1/2" -
DN25
120270 PVT 10 145 351 92.6 173 5 2 1 1/2" -
DN25
120270 SST 12 174 351 92.6 173 5 2 1 1/2" -
DN25
070410 PVT,
PPT, PCT
7 102 492 130 86 4 1 2" - DN32
070410 SST 7 102 492 130 86 4 1 2" - DN32
070580 PVT,
PPT, PCT
7 102 696 183 124 4 1 2" - DN32
070580 SST 7 102 696 183 124 4 1 2" - DN32
040830 PVT,
PPT, PCT
4 58 1000 264 173 3 1 2" - DN32
040830 SST 4 58 1000 264 173 3 1 2" - DN32
All figures refer to water at 20 °C.
The suction lift applies to filled suction line and filled liquid end - when
installed correctly.
Data Value Unit
Reproducibility ±2 % *
* - when installed correctly, under constant conditions, at least 30 %
stroke length and water at 20 °C
14.2 Shipping weight
Types Material version Shipping weight
kg
120145 ... 120270 PVT 22
SST 26
070410 ... 040830 PVT, PPT, PCT 24
SST 29
S3Ba under 60 Hz operation
Precision
Technical data
46