Protimeter Non-Invasive
Moisture Meter
Instruction Manual
WƌŽƟŵĞƚĞƌ
Aquant
REL
DRY
Question and Answer IconNeed help?

Do you have a question about the Protimeter Aquant BLD5765 and is the answer not in the manual?

Protimeter Aquant BLD5765 Specifications

General IconGeneral
ModelAquant BLD5765
TypeMoisture Meter
Measurement Range (relative)0 to 100
Resolution0.1
Depth of MeasurementUp to 19mm (3/4 inch)
DisplayLCD
Operating Temperature0°C to 40°C
Storage Temperature-20°C to 60°C (-4°F to 140°F)
Battery Type9V

Summary

Safety Considerations

Calibration and Recalibration

Accuracy specifications are valid for one year; recalibration is required afterward.

Proper Operation Guidelines

Operate the instrument properly for its intended purpose and within specified parameters.

Search Mode Operation

Measurement Depth and Mode

The non-invasive mode gives relative readings up to 19mm/3/4" beneath the surface.

Ideal Use Cases

Ideal for rapid surveys of solid walls and floors to pinpoint areas of concern.

Alternative to Pin-Type Measurement

Used when electrode pins are impractical or undesirable, like behind tiles or wallpaper.

Surface Moisture and Conductors

Surface moisture has little effect; conductors within material may cause high readings.

Reference Mode

Storing a Reference Reading

Measure until stable, then press and hold the play button for 2 seconds to store the reading.

Interpreting Reference Readings

Shows if material is above or below the original reference reading.

Operating the Aquant

Switching On

Press the ON/OFF button; the LCD displays all segments and sweeps the LED bar graph.

Measurement Display

Numeric measurement and color LED (DRY, AT RISK, WET) based on the measurement shown.

Measurement Reading Ranges

DRY (70-169 Green), AT RISK (170-199 Yellow), WET (200-999 Red).

Settings Configuration

Entering Settings Mode

Press and hold the play button, then press ON/OFF button until the version number displays.

DRY, AT RISK, WET Indicator Settings

Set whether the DRY, AT RISK, WET indication on the display needs to be switched ON or OFF.

Buzzer ON/OFF Settings

Turns the Buzzer ON or OFF. Use play button to change; ON/OFF button to save.

Backlight ON/OFF Settings

Turns the Backlight ON or OFF. Use play button to change; ON/OFF button to save.

Auto Off Time Settings

Set automatic shutdown time between 1 and 6 minutes, or disable it.

Advanced Features and Maintenance

Battery Low Indication

A symbol on the screen indicates the battery is low and needs replacement soon.

Holding/Freezing the Reading

Press the ON/OFF button during measurement to freeze the reading and display 'HOLD'.

Battery Replacement Procedure

Instructions for removing the battery lid, replacing the battery, and ensuring correct polarity.

Technical and Physical Specifications

Operating Conditions

Temperature range: 0°C to 50°C. Humidity: 0 to 90% RH, non-condensing.

Measurement Specifications

Non-invasive, up to 3/4" (19mm) deep. Readings: 70 to 999.

Physical Specifications Summary

Includes power source, size, weight, buzzer details, and regulatory compliance.