Model | BLD5365 |
---|---|
Type | Moisture Meter |
Power Supply | 9V battery |
Measurement Range (Temperature) | -20 to 60 °C |
Accuracy (Temperature) | ±1 °C |
Display | LCD |
Operating Temperature | 0 to 40 °C |
Storage Temperature | -20 to 60 °C |
Humidity Range | 0 to 90% RH |
Non-Invasive Moisture Range | 0 to 100% |
Accuracy (Moisture) | ±2% |
Caution regarding sharp WME pins and protective cap usage.
Calibration is valid for one year; recalibration is required thereafter.
Operate within parameters; readings are for judgment, not definitive.
Uses electrical conductance to measure material moisture between two electrodes.
How to verify WME mode and perform measurements using the instrument's pins.
Notes on actual %mc versus %WME values for wood and other materials.
Connect and utilize the Heavy Duty Moisture Probe for hard-to-reach measurement points.
Drill clearance holes and insert probes for deep moisture readings in walls and floors.
Readings precise to contact area; %mc for wood, %WME for other materials.
Use Calcheck to verify Measure mode calibration; target reading 18.2 ±1.0.
Detects moisture up to 19mm deep; ideal for rapid surveys of walls and floors.
Use as alternative to Measure mode; ensure flat surface contact with material.
Press and hold button for 2 seconds to store a reference reading.
Press the ON/OFF button to activate the instrument.
Use the mode button to toggle between WME (Pin) and REL (Search) modes.
Numeric measurement and color LED (DRY, AT RISK, WET) indicate moisture condition.
Take a reference measurement, then press button for 2 sec to enter Reference Mode.
Press/hold mode button, then ON/OFF until version number appears to enter Settings.
Set ON/OFF for moisture condition indicators on the display screen.
Enable or disable the audible buzzer for key tones and measurement indications.
Enable or disable the display backlight for improved visibility.
Set automatic shutdown time (1-6 min) or disable auto-off feature.
A symbol appears on screen indicating low battery requiring replacement.
Press ON/OFF button during measurement to freeze and hold the displayed reading.
550mAh battery lasts over 20 hours; low battery indicator signals replacement needed.
Remove screw, slide lid downwards to access and replace the battery.
Temperature range 0-50°C; Humidity 0-90% RH non-condensing.
Pin probe range 7.9-99% (%MC wood/%WME); non-invasive up to 3/4" deep.
Powered by 9V battery; dimensions 19x6.5x5cm; weight ~240g.