1. Room temp calibration: Calibrate the temp detected by room sensor.
2. Floor temp calibration: Calibrate the temp detected by floor sensor.
3-4. Frost Protection Mode: Frost protection allows the thermostat to turn on if the temperature drops
below 5 degrees even when it is not programmed to. displays when you turn off the thermostat.
5. Sensor selection:
00 Room sensor: Run by room sensor.
01 Floor sensor: Run by floor sensor.
02 Both sensors: Run by room sensor with floor temp limit.
6. Floor temp limit: If you choose both sensors, floor temp limit must be set to protect floor.
7. Temp unit: °C and °F can be selected.
8. Output delay: This option help you avoid inadvertent operation on heating.
9. Switching Differential: The number of degrees the temperature has to change before the unit switches
on/off. The default is 1 degree so if the temperature is set to 21 degrees the thermostat will switch on at 20.5
degrees and off at 21.5 degrees. 0.5 degrees either side of 21.
10.Reverse output: This function works for the cooling system. When the temp is 1°C higher than set temp,
the thermostat will disconnect the cooling system. otherwise, it will connect the cooling system.
11. Schedule: Select a weekly schedule for the Edit. There are 2 options:
7: each day from Mon to Sun can be set individually.
5+1+1: 5 days from Mon to Fri have the same events, Sat and Sun can be set individually.
12. Adaptive function: After several days of installation and use, Adaptive function ensures that the required
temp has already been reached when the next event begins.
13. Reset: All parameters are restored to default values.
ADVANCED SETTING