Advanced Configuration AP-4000/4000M/4900M User Guide
Alarms
109
Syslog
The Syslog messaging system enables the AP to transmit event messages to a central server for monitoring and
troubleshooting. The access point logs “Session Start (Log-in)” and “Session Stop (Log-out)” events for each wireless
client as an alternative to RADIUS accounting.
See RFC 3164 at http://www.rfc-editor.org for more information on the Syslog standard.
Figure 4-40 Syslog Configuration Screen
Setting Syslog Event Notifications
Syslog Events are logged according to the level of detail specified by the administrator. Logging only urgent system
messages will create a far smaller, more easily read log than a log of every event the system encounters. Determine
which events to log by selecting a priority defined by the following scale:
Configuring Syslog Event Notifications
You can configure the following Syslog settings from the HTTP interface:
Enable Syslog: Place a check mark in the box provided to enable system logging.
Syslog Port Number: This field is read-only and displays the port number (514) assigned for system logging.
Event Priority Description
LOG_EMERG 0 System is unusable
LOG_ALERT 1 Action must be taken immediately
LOG_CRIT 2 Critical conditions
LOG_ERR 3 Error conditions
LOG_WARNING 4 Warning conditions
LOG_NOTICE 5 Normal but significant condition
LOG_INFO 6 Informational
LOG_DEBUG 7 Debug-level messages