Mains Supply ChromaZone(s)
mains cable
WARNING - THIS APPLIANCE MUST BE EARTHED
For safety we recommend the use of a Residual Current
Circuit Breaker. An RCCB MUST be used when powering
e.g. ChromaFixtures in wet environments.
Electronics On/Off Switch Indicator Neon
Electronics Mains Fuse
- The works correctly on any
mains voltage from 85-277 VAC, 50-60Hz, (self adjusting).
Power consumption: CZ6 - 100 Watts, CZ12 - 200 Watts
depending on the number of fixtures connected and their output
levels. Please see the table shown below for more information.
A with locking IEC female connector attached is
supplied (not supplied with IP Zones). To unlock the IEC
connector, pull/side the red tab towards yourself then pull
connector out. The other end of the cable should be fitted with a
suitably approved and rated mains plug. Note: in some countries
it is a requirement that such a plug be fitted by a qualified
electrician.
with built in .
: 5 Amp, HRC, 5x20mm.
Pulsar's Chroma Lighting Fixtures - ChromaStrips ,
ChromaTubes , ChromaPanels , CAR111
ChromaScapes , CBAT17 , ChromaBatten50 ,
ChromaHearts , ChromaInGround , ChromaFlood50 ,
ChromaPoint , ChromaInGroundMR16SS , etc
ChromaFixtures Leaflet
ChromaZone Max Fixture
Loading Data
ChromaZone ,
(User Interface Module)
DMX D M X
CZ6/12
.
TM
TM TM TM
TM TM TM
TM TM TM
TM TM
TM
., contain
state of the art, high brightness, high efficiency Red, Green and
Blue LEDs. These three primary colours can be mixed together
to make an incredible pallet of 16.7 million colours.
Please see the for details of the
luminaires themselves and page 3 -
which will inform you of how many fixtures you may
put on the outputs of different ChromaZones.
The has numerous chases and effects built in
making it possible to achieve fantastic effects without
programming. These internal effects can be selected via the UIM
on the lid of the unit in Stand Alone
mode or from a controller using a digital ( igital ultiple )
signal.
When receiving a signal the can operate in 3, 6, 9, 10, 36,
42 or 46 Channel Modes Please see the lid printing page for
details of these Operating Modes, how to select them, Channel
Listings, and further information.
Each ChromaFixture requires a +24VDC supply and three 0 to
+10V control signals to control the level of Red, Green and Blue.
These control signals and the low voltage power are provided by
the CZ12 and CZ6 controllers which can drive up to 12 or 6
ChromaFixtures respectively.
ChromaZone12 200W - Mk2
TM
CZ12-200
ChromaZone6 100W - Compact
TM
CZ6-100C
ChromaPSU2 PSU
TM
CPSU2
Cable Colours
Green/Yellow =
Brown =
Blue =
Earth / Ground
Live / Phase / Hot
Neutral
ChromaFlex Grey 5 Core Multiway Cable
8075G
8075SUB
ChromaFlex Submersible 5 Core Cable
CZ12-200IP ChromaZone12 200W - IP65
TM
Model
Outputs
Max Load Control
50W
17W CP300
MR16
Link
Point
Strip 25/X1 Strip X3
CZ12-200(IP)
12
200W
DMX
4
12
48 60 96
96
14.4 mts 4.8 mts
CZ6-100C 6 100W
DMX
2
6
24
30 48
48
7.2 mts 2.4 mts
CPSU2
2
35W 0-10V 0
2
81016
16
2.4 mts 0.6 mts
The CBAT50, CFLD50 and CIG50 require up to 50 Mains Watts
each which will reduce the number of products you can use per
ChromaZone e.g. 4 x CFLD50 = 200W. Do not exceed the max
mains wattage of the zone.
NB - Patents applied for. Trade Marks, Copyright, Registered
and Unregistered Design Rights apply on all Chroma
Products.
CHROMA CHROMARANGE ZONE
CHROMAZONE MAINS SUPPLY
GENERAL INFORMATION
Pulsar Light of Cambridge Limited Tel: Email: Web:, 3 Coldhams Business Park, Cambridge, CB1 3LH, England 44 (0)1223 403500 sales@pulsarlight.com www.pulsarlight.com
7571 PSU12-200IP Instructions
Question and Answer IconNeed help?

Do you have a question about the Pulsar CHROMA Series and is the answer not in the manual?

Pulsar CHROMA Series Specifications

General IconGeneral
BrandPulsar
ModelCHROMA Series
CategoryLighting Equipment
LanguageEnglish

Summary

General Information

ChromaZone Product Range

Lists various ChromaZone models and their specifications including power and type.

ChromaFixture Operation

Explains how ChromaFixtures use +24VDC supply and 0-10V control signals for R, G, B levels.

ChromaZone Effects and Modes

Details internal chases, effects, and DMX/standalone operating modes for CZ6/12.

Mains Wattage Limitation

Warns against exceeding maximum mains wattage per zone when using specific Pulsar products.

ChromaZone Mains Supply

Mains Voltage and Power Consumption

Specifies the wide AC input voltage range and power consumption of CZ6 and CZ12 units.

Mains Cable Connection

Describes how to connect the supplied IEC mains cable, including unlocking and fitting the plug.

Safety Earth and Fuse Information

Highlights the requirement for earthing, use of RCCB in wet environments, and mains fuse rating.

CZ6 & CZ12 Signals and Connections

DMX XLR Connector Pinout

Details the pin configuration for DMX input/output using 5-pin XLR connectors.

4-Pin XLR Low Voltage & DMX Output

Explains the 4-pin XLR output for LVS and DMX, and its use for powering additional units.

Wago Output Connectors

Describes the 5-pole Wago connectors for ChromaFixture outputs, providing power and signal.

ChromaFlex Cable Wiring

Provides instructions on stripping and connecting ChromaFlex cable to cage clamp connectors.

CZ6 & CZ12 Mounting Options

Wall and Ceiling Mounting

Instructions for mounting the CZ6/12 using supplied brackets, including bracket adjustment.

Safety Chain Attachment Point

Identifies the M6 hexsert for attaching a safety chain.

Fuses and Precautions

Electronics Fuse Failure

States that a blown 5 Amp fuse indicates an internal fault requiring professional service.

Output Protection and Reset

Explains the resettable fuse for 24VDC outputs and how to reset it after a fault.

Signal Input Protection

Notes that 0-10V signal inputs/outputs are protected against shorts and static damage.

CZ12-200IP Signals and Connections

IP Rated Unit Mains and Wago Connections

Details mains wiring via Wago connector and 5-pole Wago output blocks for IP rated units.

DMX Connector Wiring (IP Zone)

Shows the DMX connector wiring for the IP Zone, including DMX IN and DMX THRU.

Output Gland Installation

Instructions for drilling, tapping, and installing M12 liquid tight glands for cable entry.

CZ12-200IP Mounting

Mounting Brackets and Plates

Describes the use of supplied mounting plates for wall or ceiling installation of the CZ12-200IP.

M10 Mounting Points

Identifies M10 nutserts on the underside and top for mounting the CZ12-200IP.

General Product Information

Testing and Standards Compliance

Details portable appliance testing capabilities, electrical safety, EMC, and IP ratings.

Product Markings and Guarantee

Explains CE/ETL markings, compliance directives, and the three-year guarantee terms.

User Interface Module (UIM) Functions

LCD Display and Basic Navigation

Describes the 2-line LCD display, status indicators, and key functions for menu navigation.

Setting DMX Address and Mode

Instructions for setting the DMX start address and selecting the ChromaZone operating mode via the UIM.

Configuring Fixture and Chase Settings

Guides on setting channels per fixture, fixture number, and chase patterns using the UIM.

Channel 10 Operation Modes

Explains how to set Channel 10 as a Grand Master for RGB or Global Master via the UIM.

Input Smoothing and Termination

Details how to enable/disable input smoothing and DMX line termination for optimal signal integrity.

Low Voltage Supply and No Signal Handling

Covers enabling low voltage supply and configuring the unit's behavior when no DMX signal is received.

Stand Alone Settings Management

Describes how to view, change, and save Stand Alone settings for different signal conditions.

ChromaZone Menu Selection Overview

DMX Address and Mode Configuration

Details the UIM menu path for setting DMX address and ChromaZone operating mode.

Fixture, Chase, and Channel 10 Settings Flow

Maps out the UIM navigation for fixture number, chase patterns, and Channel 10 functions.

Signal Handling and Restore Defaults

Covers UIM options for input smoothing, LV supply, termination, no-signal use, and factory reset.

ChromaZone Software Version 4.0 Features

Software Version and Key Enhancements

Introduces v4.0, highlighting built-in chases, master dimmer, and input smoothing flexibility.

Operating Modes and Ch.10 Functionality

Details the 7 operating modes and the role of the Master Dimmer Channel (Ch.10) as Global Grand Master.

Chase Select Table Explanation

Explains the chase select table, its chase numbers, input/bit values, descriptions, and notes.

ChromaZone Channel Assignment Tables

6 and 10 Channel Modes Assignments

Details channel assignments for 6-channel and 10-channel operating modes for ChromaZone units.

36 Channel Mode Assignments

Provides channel mapping for 36-channel mode for both ChromaZone 6 and ChromaZone 12.

42 and 46 Channel Modes Assignments

Lists channel assignments for 42-channel and 46-channel modes across ChromaZone 6 and 12.

ChromaZone 12-200IP Dimensions

Important Safety Instructions

General Safety Precautions

Emphasizes reading leaflets, observing warnings, following instructions, and protecting the power cord.

Installation and Servicing Guidelines

Covers using specified mounting, referring servicing to qualified personnel, and cleaning procedures.

Environmental and Usage Restrictions

Details restrictions on use near water, blocking ventilation, and defeating safety plug features.

Related product manuals