Electrical Requirements
1. Install all equipment in accordance with the National Electrical Code and all applicable local
codes and ordinances.
2. A means for disconnection must be incorporated in the fixed wiring in accordance with the wiring
rules.
Voltage
The voltage at the motor must NOT be more than 10% above or below motor nameplate rated voltage
or the motor may overheat, causing the overload tripping.
Grounding and Bonding
Install, ground, bond, and wire motor in accordance with local or national electrical code. Make sure to
permanently ground the motor. Use green ground terminal provided under motor canopy or access
plate. Use the appropriate size and wire type required by code. Connect motor ground terminal to
electrical service ground.
Reference NEC codes for all wiring standards including, grounding, bonding, and general wiring
procedures.
Wiring
If the pump comes with a cord and plug, no wiring is needed. In some areas, power cords are
not provided to local electrical standards. Wire pump according to local electrician codes. Follow
the instructions below for wiring.
WARNING- All electrical wiring must be performed by a licensed electrician.
WARNING- All electrical wiring must conform to local codes and NEC regulations.
WARNING- Use copper conductors only.