TROUBLE SHOOTING
Before contacting the retailer for replacement, check the below first to see if it can solve the problem:
Problem Cause Solution
The air
conditioner does
not function.
No power supply.
Connect to a functioning power outlet
and switch on.
Timer function is active.
Deactivate Timer function.
The air
conditioner does
not seem to
perform.
open, many
people, or a heat source in the room.
Close doors and windows, and remove
Clean or replace the filter(s).
Air inlet or air outlet blocked. Remove the blockage.
Room temperature lower than the
selected value.
Change temperature selection.
The unit is noisy. Unit stands uneven.
Place on an even, solid surface (less
vibrations).
The compressor
does not work.
The overheat protection is probably
activated.
Wait 3 minutes until the temperature has
decreased, then turn on the unit again.
The remote
control does not
function.
Make sure the remote control is correctly
aimed at the control panel.
Remote control signal not detected by
The batteries are drained.
Cautions: Switch off the unit and unplug it immediately if anything abnormal happens. Then contact a
qualified electrician.
SPECIFICATIONS
Permissible excessive operating pressure
(Suction/Discharge): 1.0MPa/3.5MPa
Maximux allowable pressure (Low pressure
side/High pressure side): 1.5MPa/5.5MPa
Refrigerant/Charge: R410a/615g
Power Supply: 220-240V/50Hz
Rated input (cooling): 1750W
Dimensions (WxHxD): 500x840x390mm