27
the component inside the module. Contact your local distributor for further
help.
Symptom: The switch button pops up and the battery still has output.
Possible condition: If the battery can still communicate or the indicator light
flashes normally, Switch button cannot be disconnected, switch failure.
Contact your local distributor for further help.
3
Communication serial connection wake-up
Symptom: After the first device is powered on (Press the button to start or
Voltage Activated Circuit), only some of the devices are powered on
successfully (light blinks)
Inspection steps:
(1) According to the communication cable wiring order, if a device and its
subsequent devices fail to power on, please check if the communication
cable between the device and the previous device is loose, misconnected
or if the wire is broken.
(2) Follow the "single device power on" problem to investigate.
4
Cascade battery power off
Symptom: After the first device is powered off , only some of the devices
are powered down successfully (light blinks)
Inspection steps:
(1) According to the communication cable wiring order, if a device and its
subsequent devices fail to power on, please check if the
communication cable between the device and the previous device is
loose, misconnected or if the wire is broken.