9. Remarks
Recycle and disposal
In case a battery (normal condition or damaged) needs disposal or needs
recycling, it shall follow the local recycling regulation (i.e. Regulation (EC) Nº
1013/2006 among European Union) to process, and using the best available
techniques to achieve a relevant recycling efficiency.
Storage, Maintenance and Expansion
1) It is required to charge the battery at least once every 6 months, for this
charge maintenance make sure the SOC is charged to higher than 90%
2) Every year after installation. The connection of power cable and screw are
suggested to be checked. Make sure there is no loose, no broken, no
corrosion at connection point. Check the installation environment make
sure it is suitable for IP67 battery system.
3) If the battery is stored for long time, it is required to charge them every six
months, and the SOC should be higher than 90%.
4) A new battery module can be added onto an existing system at any time.
Please make sure the new battery is acting as the master. The new
module, due to a higher SOH may have a difference on SOC with existing
system, but it will not affect the parallel connection system performance.