20
Caution
If the ambient temperature is out of the operating range, the battery stops
operating to protect itself. The optimal temperature range for the battery pack
to operate is 10°C to 40°C. Frequent exposure to harsh temperatures may
deteriorate the performance and life of the battery.
5.4 Installation method of multiple batteries
The battery can be placed flexibly according to the actual site environment. If
the battery is placed on a vehicle or a mobile object, the battery needs to be
well fixed. The upper surface of the battery is flat, the battery and the vehicle
can be fixed with a pressure strip in the horizontal or vertical direction.
1) Place the battery in the designated location;
2) Fix the battery modules tight with vehicle or other objects;
3) Connect the power cables and communication cables according
according to customer's configuration;
4) Press the Power button from the last battery in order to turn it on.
Diagram of battery power cable connection: