Contact SegenSolar (PTY) Ltd | e: info@segensolar.co.za | t: 08780 20663
1) Cable connection for RS485:
Make sure all dip switches of master batteries are R0XX, then turn ON batteries. R: is the
baud rate of RS485 needed, all master batteries shall be the same.
After all batteries are in running mode, the buzzer of master battery in group1 will ring
3 times. This means that all groups are online.
The interruption of each RS485 command shall ≥ 1s.
Figure 22: RS485 bus communication cable connection diagram for Pylontech batteries