CONTENTS
PAGE
1. INTRODUCTION 4.
2 FEATURES 4.
3 . FUNCTIONAL DESCRIPTION 5 .
3 .1 OPERATING MODES 5 .
3.2 ENTRY / EXIT MODE 5.
4 . ZONES 6 .
4. 1 ENGINEER PROGRAMMABLE ZONES 6.
4.2 24 HOUR ZONES 6.
5. CONTROLS AND FUNCTIONS 7.
6 . USER FACILITIES 8 .
6. 1 FULL SETTING THE PANEL 8.
6. 2 PART SETTING THE PANEL 8.
6 .3 UNSETTING THE PANEL 8 .
6. 4 ACTIVATING THE PERSONAL 8.
ATTACK ALARM
6.5 ACTIVATING THE FIRE ALARM 8.
6. 6 TURNING CHIME ON AND OFF. 8.
6.7 RECALLING EVENT LOG 9.
6. 8 OMITTING ONE OR MORE ZONES 9.
6. 9 CLEARING THE EVENT LOG 9.
6.10 CLEARING THE DISPLAY AFTER
AN ACTIVATION 9.
6.11 CHANGING THE USER CODE 10.
6.12 SYSTEM TEST MODE 10.
6.13 WALK TEST MODE 10.
7 . LED FUNCTIONS 1 0.
8 . TROUBLESHOOTING 1 1 .
9 . USER QUICK REFERENCE GUIDES 1 3.
RINS 049 ISSUE-2
3
14
Question and Answer IconNeed help?

Do you have a question about the Pyronix Conqueror and is the answer not in the manual?

Pyronix Conqueror Specifications

General IconGeneral
BrandPyronix
ModelConqueror
CategoryControl Panel
LanguageEnglish

Summary

Introduction

Features

Functional Description

Operating Modes

Describes Day, Set, Full set, Part set 1, and Part set 2 modes of the alarm panel.

Entry / Exit Mode

Details the panel's behavior during entry and exit sequences, including timers and zone triggers.

Zones

Engineer Programmable Zones

Explains zone types like Entry/Exit, Access, Immediate, Omitted, and their functions.

24 Hour Zones

Defines 24-hour zones such as Personal Attack, Tamper, and Fire, and their alarm behavior.

Troubleshooting

Controls and Functions

User Facilities

Full Setting the Panel

Instructions for setting the alarm panel using user code or easy-set methods.

Part Setting the Panel

Guide to setting specific zones (e.g., downstairs or upstairs) for partial arming.

Unsetting the Panel

Procedure for unsetting the alarm system using the entry/exit route and user code.

Activating the Personal Attack Alarm

How to manually trigger the Personal Attack alarm via keypad entry.

Activating the Fire Alarm

Instructions on how to activate the fire alarm function from the panel.

Turning Chime On and Off

Method to toggle the chime feature for entry/exit zones in day mode.

Recalling the Event Log

Steps to view past alarm events and system activity from the event log.

Omitting one or more zones

Procedure for temporarily disabling specific zones, e.g., due to faults.

Clearing the Event Log

Instructions for users to clear the system's event log.

Clearing the display after an activation

How to clear alarm indicators from the panel display after an event.

LED Functions

User Quick Reference Guide

Changing User Code

Steps to change the existing user access code to a new one.

System Test Mode

How to enter system test mode to verify all panel components are functional.

Walk Test Mode

Procedure to enable walk test mode for checking zone activation and LED indication.