Page: 5
3. Writing Texts on the keypad
On the Enforcer 32-WE it is possible to label the following:
- Inputs – 2 labels: Input Number and Location
- Area Names
- Site Name
- Keypad/Reader – 2 labels: Keypad Number and Location
- Input and Output expander location descriptions
- User Names
The Enforcer 32-WE incorporates a predictive text feature (T9 type). For example, enter ‘B’ and
‘Bedroom’ will be displayed. If the word that is required doesn’t appear, then type the word letter by
letter.
To type a word, press the relevant button the appropriate number of times – e.g. for the letter ‘k’
press 5 two times, or for the letter ‘s’ press 7 four times. For punctuation marks, press the 1
button multiple times until the desired character is shown.
Button meanings:
The following alpha-numerical buttons are used Other meaning of the buttons
a = makes the character into a capital a = Status Area A
c = clears letters / adds a space
b
= Status Area B
[ = moves cursor left
c
= Status Area C
] = moves cursor right
d
= Status Area D
d
= Press to Enter Master Manager Mode
f
= Press for 2 sec to generate Fire alarm
p
= Press for 2 sec to generate PA alarm
4. The Engineer Menu
The system is programmed from the Engineer Menu. To enter the Engineer Menu the panel must be in
a disarmed state. Whilst in Engineer Mode all tamper alarms (including case tamper), will be disabled.
4.1 Navigating in the Engineer and User Menus
x
= “NO” - Press to move forward when in Engineer or Master Manager mode
b = “BACK” - Press to move backward when in Engineer or Master Manger mode
t
= “YES” - Press to enter in a submenu or option when in Engineer or Master Manger mode
t
= Press to move from one option into another option while in a submenu
a
= Press to quick exit the Engineer Menu from any main menu (written in capital letters)
c
= “CANCEL” - Press to move back from one programmable option to the previous option.
4.1.1 Main Menus and Sub Menus
A Main Menu item is identified by:
The maintenance LED is flashing slowly
The menu item will be in capital letters
A Sub-Menu is identified by:
The maintenance LED is flashing rapidly
The menu item will be in small letters with a
question mark (?).
In order to navigate in the menu system, one has to answer to the questions in the main and sub
menus. For example, if the question is “WIRELESS DEVICE CONTROL?” is displayed, then press t or
x depending on the answer.
Pressing t will enter a sub-menu called “Control Inputs?” in this example. Pressing t will enter
the programmable options of this submenu. Pressing x will exit the individual option, move up
from one sub-menu to the next sub-menu or back to the main menu.

Other manuals for Pyronix Enforcer 32-WE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pyronix Enforcer 32-WE and is the answer not in the manual?

Pyronix Enforcer 32-WE Specifications

General IconGeneral
BrandPyronix
ModelEnforcer 32-WE
CategorySecurity System
LanguageEnglish

Related product manuals