EasyManuals Logo

Pyronix Enforcer 32-WE Programming Reference Manual

Pyronix Enforcer 32-WE
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #17 background imageLoading...
Page #17 background image
Page: 17
Access Control
Allows the reader to control doors fitted with electrical locks. On the readers there are 2 inputs that
also can be outputs. They can be connected to the lock for opening and controlling the door.
Lock Open Time: This is the time the door release is going to be active when a valid tag is
presented.
Door Open Time: This is the time the door is allowed to be open before triggering an alarm.
Door Name: Enter the name of the door such as Front Door.
Door Location: Enter the location of the door such as First Floor.
NOTE: Access control falls outside the scope of EN50131-1.
Disarm Only
Allows the reader to be used to disarm the system only.
Device Disarms: This feature programs which area(s) the reader can disarm.
Device in Area: This feature programs in which area(s) the reader is active.
Device Name: Enter the name of the door such as Front Door.
Device Location: Enter the location of the door such as First Floor.
Entry Control
Allows the reader to be used as arm/disarm Device and access control.
Device Arms Areas: This feature programs which area(s) the reader can arm.
Device Disarms: This feature programs which area(s) the reader can disarm.
Device in Area: This feature programs in which area(s) the reader is active.
Lock Open Time: This is the time the door release is going to be active when a valid tag is
presented.
Door Open Time: This is the time the door is allowed to be open before triggering an alarm.
Door Name: Enter the name of the door such as Front Door.
Door Location: Enter the location of the door such as First Floor.
Keypad Device Type
Device Arms Areas: This feature programs which area(s) the keypad can arm.
Device Disarms: This feature programs which area(s) the keypad can disarm.
Device in Area: This feature programs in which area(s) the keypad is active.
Door Name: Enter the name of the door such as Front Door.
Door Location: Enter the location of the door such as First Floor.
5.7 Program Timers?
Timers Description Options
Entry Time 1
Entry Time 2
Programmes the entry time for each area. If entry time is started at a door
programmed in multiple areas, the longest time will apply. Entry time 1
will apply to any inputs programmed as “Entry Delay 1” type, and Entry
Time 2 will apply to any inputs programmed as “Entry Delay 2” type.
Ensure that timer is no longer than 45 seconds in order to comply with
EN50131-1.
0-255 seconds
Exit Time Programmes the exit time for each area. If the system is being armed at
an arm device programmed as ‘IN’ multiple areas, the longest of those
times will apply.
0-255 seconds
Bell Time Cut off time for external sounder. Separate for each area. Repeat above
steps for each of the Enforcer 32-WE areas programmed.
0-15 minutes
Bell Delay Delay after burglary alarm before bell activation.
NOT valid within 3 minutes of final arm, or after entry time started. If
‘Silent 1st Alarm’ selected in alarm responses, delay commences at
confirmed alarm.
0-20 minutes
Strobe Time The duration of time the strobe output remains live after the bell time
ends, ‘99’ means endless.
0-99 minutes
Number Re
arms
Number of times system re-arms after bell time ends. Re-arm number
applies to each area, and does not affect emergency alarms. ‘9’ = ‘always
re-arm’.
0-9
AC Fail Delay Time delay before mains failure or technical alarm signalled. ‘250’ = never
alarms. System change-over to battery supply and associated ‘alert’
indication is always immediate. Mains Fail message on keypad not
permitted until valid code entry.
0-250 minutes

Other manuals for Pyronix Enforcer 32-WE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pyronix Enforcer 32-WE and is the answer not in the manual?

Pyronix Enforcer 32-WE Specifications

General IconGeneral
BrandPyronix
ModelEnforcer 32-WE
CategorySecurity System
LanguageEnglish

Related product manuals