Matrix 6/816 User Manual
RINS545-7 Page 11
3.6 Activating Alarms from the Keypad
3.6.1 Personal Attack
Hold down the = button
for 2 seconds.
The
Personal Attack alarm will either activate all sounders or will be silent (the
event will only be reported to the Central Monitoring Station) depending on how
the system is programmed by the engineer.
3.6.2 Fire Alarm
Hold down the '
button
for 2 seconds.
The
Fire alarm will activate all sounders. External sounders will emit an intermittent
tone and keypad sounders will emit a series of three rising tones.
3.6.3 Medical Alarm
Hold down the ; button
for 2 seconds.
The
Medical alarm will activate all sounders. Keypad sounders will emit a high
frequency repeated tone.
3.7 Duress Arming / Disarming
3.7.1 What is a Duress Code?
A duress code is a personal user code that the alarm panel recognises as being entered under duress. By this
we mean that the user has been forcibly made to enter their user code to disarm or arm the panel by another
person.
The alarm panel treats this code like a proper user code and behaves as normal. The duress code will arm or
disarm the system as normal. However, an emergency message is sent to your central monitoring station
indicating that the panel was armed/disarmed under duress.
Method 1
Reverse the 3
rd
and the 4
th
digits of your user code when entering it into the keypad.
For
example, enter 1 2 4 3 instead of 1 2 3 4.
Method 2
Enter the duress code as programmed on your system.
When you enter the duress code, the panel will act normally, however the duress event will be reported to the
Central Monitoring Station.
3.8 Display Event in FTA Mode
Fragment
Indicator
Meaning
EE K
Entry time expired after Entry/Exit or Shunt Keypad zone triggered. The system
has not been disarmed within the predetermined time.
pq...qy
K
Zone ? 01...16 triggered: Access, Immediate or 24Hr type.
pq...qy
K X
Zone ? 01...16 triggered: Personal Attack type.
pq...qy
K Z
Zone ? 01...16 triggered: Fire type.
PA K X
PA alarm activation from keypad.
F K Z
Fire alarm activation from keypad
qu K
Medical alarm activation from keypad.
L K
Telephone line fail alarm
pq...qy
K S
Zone ? 01...16 triggered: Tamper type.
Tr K S
Expander tamper the expander module is no longer detected (Matrix 816 only).
Tt K S
Siren tamper the siren connected to PGM7 is no longer detected
(Matrix 816 only).
Ti K S
Key press tamper 16 wrong key presses in armed mode.
Ë = Flashing Icon
NOTE: The numbers of the activated zones which are still open while viewing in FTA mode will be
flashing.

Other manuals for Pyronix Matrix 6/816

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pyronix Matrix 6/816 and is the answer not in the manual?

Pyronix Matrix 6/816 Specifications

General IconGeneral
BrandPyronix
ModelMatrix 6/816
CategoryControl Panel
LanguageEnglish

Related product manuals