Matrix 6/816 User Manual
RINS545-7 Page 19
5.2 Entry/Exit Procedure
Follow the procedures below for arming the alarm panel before leaving the premises, and for entering the
premises and disarming the alarm panel:
ENTRY
When the panel is armed, entering the premises using the Entry/Exit zone will trigger the Entry
timer. The system counts down the preset entry time and the internal sounder warning tone is
heard. Access zones triggered during the countdown period will be ignored. If no correct user code
is entered before the end of count down period, or entry to the premises has been undertaken by
an incorrect route, the panel will go into the alarm state.
EXIT
After entering a user code the system will count down the preset exit time and the internal
sounder will beep. After the procedure is complete, the internal sounder beep will cease and the
panel will be armed. If any of the zones are opened whilst the panel is arming, the panel will
generate an error tone.
5.2.1 Available Arm Options
Timed Exit You can exit the premises while arming within a specified period of time depending on the
condition of the zones. After you start arming the panel the exit time countdown timer will
operate for the pre-set time and the internal sounder high tone will be heard. You should leave
the premises within this time period by the designated route. Upon the end of countdown, if
all zones under arming are closed (not activated), the internal sounder will emit the
confirmation tone and the system will be armed. If any of the zones (Entry/Exit, Access and
Immediate) are triggered during exit time, the countdown will hold and the internal sounder
tone will change to the error (low) tone until the activated zones are closed. After the zones
are closed the countdown timer will proceed.
Final Door There is no time limitation for leaving premises while arming and the system will be armed at
any time when the final door is closed. The internal sounder high tone beep will be heard
when arming starts until the door is closed. If the door is opened and/or other zones are
activated while arming, the internal sounder tone will change to the error (low) tone. After the
door is closed there will be a time delay (0…99 seconds, 7 seconds by default) until the system
is armed and the internal sounder will mute. A single confirmation tone will denote the delay
time start (ready to arm) and expiry (armed).
Silent Arm You may leave premises while arming within a pre-determined period of time by the
designated route without any audible indication. Upon expiry of the exit time the system will
be armed if all zones under arming are closed. Otherwise, arming of the system will be
cancelled and the panel will generate an alarm signalled by internal sounder warning only.
Forced Arm Arming takes place within a pre-determined period of time irrespective of whether all of the
zones under arming are closed. After you start arming the panel the internal sounder high
tone will be heard. If any of the zones under arming are open (activated) the internal sounder
will change to the error (low) tone. Upon expiry of the exit time the panel will be armed and
the sounder will turn off. Open zones (if there are any) will be omitted (bypassed) until closed.