CONNECTIONS: POWER SHARING BETWEEN HIGH & LOW IMPEDANCE OUTPUTS
The ISA 300T, ISA 500T and ISA 800T models are equipped
with autotransformer-coupled, high impedance (High-Z)
outputs. They are also equipped with low impedance (Low-
Z) direct outputs. The high impedance outputs are not
isolated.
The unique feature of the T model outputs is that you can
connect loads to the high impedance AND low impedance
outputs for maximum system flexibility. If the total output
power of a channels high impedance connections does not
exceed 20% of maximum rated power, then any of the rated
low impedance load values can be connected at the low
impedance terminals. For applications where the high
impedance output power is 20-50%, then 8 or 16 ohm
loads on the low impedance output is OK. If the high
impedance output power is 50 to 80% of rated power, then
16 ohm loads are OK. If the total output of a channels high
impedance connections exceeds 80% of that channels
maximum rated power, then DO NOT USE the low imped-
ance outputs. The following chart is a useful guideline:
Power sharing between “Direct” (Lo-Z) and “Distributed” (Hi-Z)
Outputs: Acceptable Low-Z loads as a function of High-Z output
power. NOTE! “Caution” advisory means that this load impedance
may be suitable for low power or low duty cycle applications.