QTIA
D
66
Preamplifier
-
Programming
Instructions
(from
serial
number
210600)
please
read
the
main
instruction
book
first,
to become
fully accustomed
with
your
66
preamplifier
operation,
before
trying
to use
the special
programming
feature
explained
below.
There
is
a special
programming feature
which
is not
visible
in normaloperation.
This
allows
you
to
programme
and
store specific
settings
of step,
tilt
,
filter
and
volume
for
each
input
except
TAPE.
You can
move
from lhe
'programmed'mode
and
back
by
pressing
any
input button, except
TAPE, 3 times.
You are
in the
'Normal'
mode
when
the'STEP
TILT
FILTER'
icons, in the display,
are
lit
and
in
'programmed'
mode
when
they
are
not.
To
programme
an
input
press
the
input button 3
successive
times
followed by STAND-BY
(da-da-da-dum).
The
'STEp
TILT
FTLTER'
icons and
a single
top segment
of
the
'volume'
display
together
with the
'flag'for
the
input selected,
will
'flash'
to show
it is
in
the
'programming'mode.
tf the 66
preamptif ier switches
to stand-by
you
have
got
the timing
wrong
!. Possibly too
fast or
too slow.
Don't
worry
just
press
the
STAND-BY
button again,
to switch
on, and
repeat the
above sfeps.
Step,
tilt
and
f ilter
f
unctions
can
now be set
as
required.
The volume can
also be
adjusted
by up
to
4 notches
above
or
below
the
nominal
setting
-
this
is
shown
by
flashing segments
either
side of
the
flashing top segment.
Press the
input button
again
to
store
the settings
and
return
to the
'programmed'mode.
lf
required a
number
of
inputs
can
be
programmed
consecutively
by
changing
inputs between
settings
and
pressing
the
last
programmed
input button a
second
time, to store
allthe
chosen
inputs and
settings
and
reveft
to the'
programmed' mode.
The 66
preamplifier
will
go
to
its
'programmed'mode
(the
display
will stop
flashing)
and
when any
input is
chosen
the stored
step,
tilt,
filter
and
volume settings
will always be
selected.
These
can of
course
be
altered,
if required,
with
the
remote
control.
Switching
to another
input and back
again
will
restore the
stored
settings.
lf
you
want
to clear
all
the
stored
settings
f rom the
memory and
revert back
lo
'flat'settings
for all
inputs,
reselect
the
'programming'mode
and
press
the CANCEL
button.
The 66
preamplifier
will
go
to
'normal'
mode
with all
stored
settings
cleared
from
its memory'
Note:
To
allow
for A
-
B
monitoring
the
TAPE
input cannot
be
programmed
and
the
volume does
not decrease
and
increase
on selection
or
if changing
inputs
when in the tape
monitor
mode.
Neither
is it
possible
to toggle
between
modes
with the
TAPE button'

Other manuals for QUAD 66