4300 Wood Stove Series (ACC)
9
Maintaining & Servicing Your Appliance
A. Quick Reference Maintenance Guide
Baf e and blanket placement is critical to heat out-
put, ef ciency and overall life of the unit. Make sure
the baf e is pushed all of the way to the back of the
rebox and the blanket is laying at.
Firebrick is designed to protect your rebox. Replace
rebricks that are crumbling, cracked or broken. If
you have an optional ash door, check to make sure
the door is closing properly.
The chimney and chimney
cap must be inspected for
soot and creosote during
the burn season. This will
prevent pipe blockage, poor
draft, and chimney res.
Always burn dry wood to
help prevent cap blockage
and creosote build-up.
Keeping the door and glass gasket in
good shape will maintain good burn
times on a low burn setting.
Check the glass frame for loose
screws to prevent air leakage.
Check the door latch for proper adjustment. This
is very important especially after the door rope has
formed to the stove face.
Start the rst inspection of your unit after the
rst 2 months of use, or if performance chang-
es, and adjust your schedule accordingly.
BAFFLE & BLANKET PLACEMENT
INSPECT FIREBRICKS & ASH COVER
(AFTER EACH CLEANING)
CHIMNEY & CAP INSPECTION
DOOR & LATCH CHECK
Step Top Models Only
Maintenance is required for safe operation
and must be performed to maintain your
warranty.
These are generic drawings and may not represent your model.