Continued installation operation
8) If users want multi-channel water supply, they can connect the water pipe
according to the gure 4.
9) After conrming that the ratings of electricity meters, wires, switch sockets and
fuses in the power system meet the energy consumption requirements of this
product, connect a separate socket in a suitable place to supply power to the
electric boiler (Fig. 5). The installation height of the socket from the ground should
not be less than 1.8m.
Comments
1. Do not place the socket in a place where water can easily enter.
2. The electrical outlet must have a reliable ground wire.
3. The socket must be kept dry to prevent leakage. The electrical installation must be
carried out by professionals.
Inspection and commissioning
1) The connection and direction of the pipeline should be reasonable and there should
be no water leakage at any connection.
2) The electrical conguration must be safe and correct, the electric boiler must be
reliably grounded, and the plug and socket must work closely together.
3) The mechanical connection must be rm and reliable.
4) Check the possible leaking parts of the casing with a test pen or multimeter to
ensure that the electric water heater works safely and normally.
5) Electric water heater must operate according to the method of use in this manual
and all performance indexes must correspond to manual.
User manual
Comments
When using the water heater for the rst time or after emptying the tank and then using it
again, you must rst ll the water heater tank with water. The method is: open the water
inlet valve, pull up the handle of the water mixing valve and turn it clockwise to the high
temperature zone, that is, start spraying water into the inner tank. When the hot water
outlet comes to bellies, it indicates that the tank is lled with water. Then turn the
handle of the water mixing valve counterclockwise to the low temperature part and push
the lever to the highest position. Closed position (as shown in Fig 6)