QubicaAMF XLi Pinspotter Motor and Gearbox Manual
400-088-038 32 Revision F
3.3.7 Oil Seal Replacement: Elevator Drive Shaft
Be sure to follow the procedures from Section 3.3.3 Oil Draining before replacing any oil seal.
Tools Required
Flat-head Screwdriver Klüber Grease (P/N 715-012-505)
Cleaner (Loxeal
®
10 or Loctite
®
7061) Installation Tool (P/N 088-004-662)
Clean Cloth Tape
1. Position gearbox with input shaft downward. Take care to not damage the sides of the gearbox or the
input shaft.
2. Remove the key from the elevator drive shaft.
3. Wrap the end of a flat-head screwdriver with insulating tape to prevent damage. Screwdriver should
be approximately 0.6” tip thickness x 0.3” tip width x 6.9” length (1.6 x 8 x 175 mm).
4. Insert the screwdriver tip between the oil seal lip and the output shaft. Take care to not damage the oil
seal seat on the shaft.
5. Use the screwdriver as a lever and the elevator drive shaft as a fulcrum to remove the oil seal from its
seat.
6. Spray cleaner (Loxeal
®
10, Loctite
®
7061, or equivalent) on a clean cloth and carefully clean the outside
(housing) and inside seat (shaft) of the oil seal. *Never use a drying or oxidizing agent such as bleach or
brake parts cleaner as they will promote rust.
7. Grease the NEW oil seal with Klüber grease.
8. Place the seal onto the body.
9. Fit the oil seal with the appropriate plastic installation tool.
10. Check that the oil seal fits correctly.
11. Fit the previously removed key back into its seat in the output shaft.
Caution! Oily rags can be a fire hazard. Dispose of them in an approved metal container only!