Parameter no. 112 - Relay to power off
Set value selects relay to be powered off when threshold is reached (defined by parameters no.
110 and 111).
Values (size is 1 byte dec):
default value 0
0 - switch between the 2 relays (power off relay 1 first, after power on, if power
consumption is still over, power off relay 2, ...)
1 - always power off relay 1 (IR external relay)
2 - always power off relay 2 (External relay)
3 - always power off both relays (relay 1 and relay 2)
Parameter no. 130 Serial Number
Read only. Unsigned Value (32bit)

Other manuals for QUBINO Smart meter

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the QUBINO Smart meter and is the answer not in the manual?

QUBINO Smart meter Specifications

General IconGeneral
Communication ProtocolZ-Wave
Weight150 g
Rated Current65 A
AccuracyClass 1
Frequency50/60 Hz
Radio ProtocolZ-Wave
Power Consumption< 1 W
Z-Wave Frequency868.42 MHz (EU)
RangeUp to 30 m indoors
Operating Temperature-10°C to +40°C