1. Intended Application for Quest 506 Dehumidifier
The Quest 506 Dehumidifier is designed to operate in temperatures between 56° and 95°F.
In order to eciently control humidity levels, the area in which the dehumidifier is to be operated must be free of water
intrusion or excessive fresh (outside) air infiltration. Before installing the Quest 506 Dehumidifier, water intrusion and
air infiltration problems should be addressed or noted in calculations.
2. Registrations
The Quest 506 Dehumidifier units conform to unified standard UL 60335-2-40.
3. Specifications @ 80°F/60% RH
Unit: Quest 506
4036600
Power (Watts):
2700
Supply voltage:
220-240 VAC -
1 Phase - 60 Hz.
Current Draw (Amps):
11.0
Rated Current Draw (Amps):
(104°F 36%)
13.6
Energy Factor (L/kWh):
3.8
Operating Temp:
56°F Min - 95°F Max
Water Removal (Pints/Day):
Eciency (Pints/kWh):
506
8.1
Air Filter (MERV-13): (2)
Size: 18" x 20" x 2"
Power Cord:
Drain Connection:
3/4 Threaded NPT
Refrigerant Type:
Refrigerant Amount:
R410A
4lb. 8oz.
Dimensions:
Width:
Height:
Length:
Weight:
Unit Shipping
28.9” 36”
33.8” 40”
44.7” 48”
280 lbs 340 lbs
14ga 10’, NEMA 6-20P

Other manuals for Quest Engineering 506