3. TERMOPID FUNCTIONING AND PROGRAMMING
(excluding model 0960 CAROLA)
Through one of the TermoPID models mounted, it is possible to adjust the
temperature of the machine boilers.
To set the temperature, proceed as follows.
Set-point temperature programming
To access the set point temperature adjustment programming, proceed as
follows:
With the termopid enabled (on), press the and keys simultaneously.
When the display shows “t1” press the key to scan the set points “t1 or
t2”.
When the display shows the required set point “t1 or t2” press ▲.
The display will show the set point temperature entered; it is then possible
to modify the value of the temperature required with the and keys.
3 seconds after the pressing of the last key, the data is stored and the
display will show the current temperature.