10
10.Temperature Calibration
The temperature should be recalibrated every time the heating element is
replaced.
1) Set the temperature of the unit to 300℃ before calibration.
2) When the value of temperature is stable, measure the air outlet
temperature of the handle with QUICK 196 and record the reading.
3) Then long press the "▲" and "▼" of TEMP at once to enter the
temperature calibration mode.
4) Press the "▲" and "▼" of TEMP to change the digit, then
press "COOL" to confirm.
5) Repeat the above steps to calibrate until displaying no temperature
error.
Note: If QUICK196 is not available, it is recommended to place the
temperature measuring device of the thermometer external sensor 3
5mm away from the nozzle for temperature measurement.