Section II - QCS100
Filter Replacement
Replace the filter when the water being
discharged is too cloudy or the filter is
clogged.
notiCe
Observe the legal regulations in your
country pertaining to the use and
handling of filters, particularly with
regard to keeping a spare filter set.
Use only manufacturer approved filter sets
in order to ensure operational reliability
and warranty compliance.
Remove the PE bag prior to inserting the
filters and use it as a packaging for the
used filter.
Filter Replacement Procedure
Shut off condensate inlet.
Open the QCS cover, and remove the
filter mat and the inlet.
Slowly remove the used pre-filter and
the main filter from the container and
let them drain.
Put the drained filter set into the
PE packaging and dispose of in
accordance with local regulations.
♦
♦
♦
♦
Insert a new filter set into the filter
receptacle.
Insert the filter mat into the pressure
relief chamber and re-install the cap.
Open condensate inlet.
♦
♦
♦