EasyManua.ls Logo

Quooker COMBI - Disconnecting tank

Quooker COMBI
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Disconnecting tank
In case of service.
1
3
2
4
1. Switch o
Press the on/o switch at the top of the
tank to switch it o. Do not unplug the tank
from the power socket yet.
2. Drain
Open the boiling-water tap (push-push-
turn) and the cold water of the mixer tap
and leave the water running until it runs
cold. Then close both taps.
3. Isolate
Close the main shut-o valve or the
isolation valve. Check that the Quooker
system is depressurized by opening
the boiling-water tap again. If it is
depressurized, no water should ow out of
it. Also open the hot and cold water of the
mixer tap until no more water ows from
the tap.
4. Disconnect
Unplug the LED cable from the tank cover.
Release the hose connections and pull the
plug out of the socket. Remove the inlet
reducing valve and reconnect the cold
water hose to the isolation valve using the
bre washer. Open the main shut-o valve
or the isolation valve.
E
On/off
Cold

Other manuals for Quooker COMBI