Bubble‐Up®JrInteractive™RadonRemovalSystem
13
BypassingtheUnit
Ifaproblemdevelops,theBubble‐Up®JrInteractive™unitcanbetakenoutofthewatersupplysystemwiththebypass
valve.Therestofthewatersystemwilloperatenormally,buttheBubble‐Up®JrInteractive™willnotbeabletoprovide
anyprotectionagainst
radoninthewater.
Caution!Donotcontinuetooperatethewatersupplysystemthiswayforalongtime.Correcttheproblemwiththe
Bubble‐Up®JrInteractive™andreturnittoserviceasquicklyaspossible.
Maintenance
Everysixmonths:
• Checktheoperationofthefloat,pumpcontrol,solenoidvalve,andtheblowerbyturningonawatertapand
allowingittorun.Atfirst,thewaterwillbesuppliedbythe2.1gallonwaterexpansiontank,andthenthepump
shouldturnon.A
fewminuteslater,youshouldheartheblowerstartandthesolenoidvalveshouldopen.(The
unitcannotremoveradonunlesstheblowerisworking.)
• Checktheincomingflowrateonthemetercontrol.Typicalwellpumpfillratesarebetween4and7GPM.
Higherflowratesystemsare
available.
• Shutoffthewatertap.ThetankintheBubble‐Up®JrInteractive™unitshouldfillinlessthantwominutes.
• Checktheoutletoftheventlinetoensurethatitisnotblocked.
• Checkthatthemotorizedballvalveisoperatingcorrectlybycrossing
theleadsoftheterminalblockorraising
thehighwaterfloat,orwettingthefloorsensor.Thisshouldactivatethemotorizedballvalveandshutoffall
incomingwater.HoldtheRESETbuttononthefrontofthewateralarmvalvecontrolforthreesecondsto
returnthemotorizedball
valvetoitsopenpositionaftereachtest.
• Disinfecttheunitasneeded.(Pouroneounceofbleachintotheblowerattachmentnipple.)
• Replace9‐voltbatteryinWaterAlarmValveControl
Everyyear:
WerecommendthatyouhaveyourBubble‐Up®JrInteractive™unitcheckedoncea
yearbyaqualifiedinstaller.The
yearlycheckupmayincludethesesteps:
• Runrawwaterandfilteredwaterradontests.
• Replacethecartridgeinthepre‐filteranddisinfect.
• CleanthemainBubble‐Up®JrInteractive™tankasdescribedbelow.
• Disinfecttheunitasneeded.(Pour
oneounceofbleachintothepre‐filtercartridgehousing. )
• Cleanandrebuildsolenoidvalve.1/2"RebuildKitPN:BUB019Cor3/4"RebuildKitPN:BUB020C
• Checktheoperationofbothfloatswitches,lowwaterandfill.
Everyfiveyears:
Replacebothfloatswitches,lowwaterfloatand
fillfloat.
Cleaningthetank:
1. Unplugallpowercordstotheunitexceptthepumpcontroller.
2. Runawaterfaucetuntilmainstoragetankisempty.
3. Unplugthepumpcontroller.
4. SetthebypassvalvetotheBypassposition.
5. Removetheblowerandsetitto
oneside.
6. Runa3/8”ODtubedownthecenteroftheair‐watercouplerabout3feetandvacuumorsiphonoutthewater
inthebubblingchamber.
7. Undothewaterinletlineatthepointwhereitmeetstheair‐watercouplingbel owtheblower.See
figure6.