Bubble‐Up®JrInteractive™RadonRemovalSystem
7
ControlsandIndicators
Bypassvalve
ThisvalvecanbeusedtodivertthewaterflowifaproblemdevelopswiththeBubble‐Up®JrInteractive ™unit.
Thisvalvehastworedhandles,andislocatednearthebackoftheunit.SeeFigure7.Thevalvehastwopositions:
• Service‐Thisis
thenormaloperatingposition.Whenthetwovalvehandlesareinlinewithwaterflow,theunit
canremoveradonfromtheincomingwater.
• Bypass‐Whenthetwovalvehandlesareperpendiculartowaterflow,theincomingwater“bypasses”the
Bubble‐Up®JrInteractive™unit.Usethispositiononly
ifthereisaproblemwiththeunit.
Caution!WhenthebypassvalvesaresettotheBypassposition,theBubble‐Up®JrInteractive™unitcannotprovideany
protectionagainstradoninthewater.
MeterControl
ForinstructionsregardingthemetercontrolrefertotheBubble‐UpMeterControlmanual
intheappendixandonlineat
www.represcott.com
MechanicalPumpControl
ForinstructionsregardingthemechanicalpumpcontrolrefertotheBubble‐UpMechanicalPumpControlAssembly
Owner’sManualintheappendixandonlineatwww.represcott.com.
WaterAlarmValve
Thewateralarmvalvecontrolisdesignedtoidentifyleakingproblemsin
theBubble‐Up®JrInteractive™.Itisdesigned
tomonitorradonventobstruction,highwaterandfittingleaks.Itdoesthisbyincorporatingawateralarmvalvefloat
switch,wateralarmfloorsensorandwateralarmtanktopterminal blocksensortosignalthewateralarmvalvecontrol
whichoperates
themotorizedwateralarmballvalve.Seefigures13and14.
ImportantFeature:Thewateralarmvalvecanalsobeusedtocreateanynumberofremoteleakdetectionpointsby
connectingextraleadstotheleadsoftheterminalblock.
UsersGuide:
Pleasechoosethecorrectmodeon
themodeswitchshowninthepictureaccordingtotheapplication.Inthe
caseoftheBubble‐Up®JrInteractive™,theswitchshouldbeinthenormalwaterposition.Seefigure5*
Thebuzzerwillbeepifthereisaradonventpipeobstruction,highwateralarmordetectedwater
leak,andat
thesametimeasignalwillbesenttotheexternalmotorizedballvalve.Thissignalwillcausetheballvalveto
closeandcutoffthewatersupplyimmediately.
Toresetthemotorizedballvalvetoitsoriginalopenposition,holdtheresetbuttonfor
threeseconds.
Ayellowlightaccompaniedbythebuzzermeansthatthebatteryislow.Ifthisoccursreplacethebatteryas
soonaspossibletoavoidanyoverflowsduringapoweroutage.
ImportantinformationabouttheWaterAlarmValve:Thealarmonthiscontrolwillgooffif
thereiswaterinsideofthe
control.Ifthisoccurs,fullydrytheinsideofthecontrolbeforereturningittoservice.