Bubble‐Up®JrInteractive™RadonRemovalSystem
15
ThissituationcanbecausedbysimplyusingmorewateroutoftheBubble‐Up®Jrthanwhatiscomingin.Comparewater
outletflowwith“currentflow”metercontrolreadingontheBubble‐Up®Jrwhilefilling.
Afewinletflowproblemsare;lowyieldwell,wellpump
failure,cloggedplumbingorwaterfiltrationrestrictingwaterflow
fillingtheBubble‐Up®Jr.
NowaterfromtheBubbleUp(alarmissounding)
Cause:WaterAlarmValveshutwaterofftoBubble‐Up®Jr.
Example:TheBubble‐Up®JrInteractiveincludesawateralarmvalvewhichsoundsanalarmand
stopswaterfillingthe
BubbleUpwhenaleakoroverflowconditionisdetected.OncewaterstopsfillingtheBubble‐Up®Jr,continuedwateruse
willcausethelowwaterfloatswitchtostoptheBubbleUppumpfromdeliveringwaterflowtothehouse.
Examples:Thealarmconditionsto
causethewateralarmvalvetocloseandstopwaterfromenteringtheBubble‐Up®Jr
are; 1‐ the water sensor box detects water on the floor around the Bubble‐Up® Jr 2‐ the water sensor terminal block
detectswaterontopoftheBubble‐Up® Jror3‐thehigh
waterfloatswitchsenseshighwaterinthemaintank.
Theseconditionsarecausedbywaterdetectionduetohighwaterlevels,waterleaks,condensationEtc.
AlsoiftheairventpipingisrestrictedtheBubble‐Up®Jrblower cannotfreelyblowtheairoutoftheBubble‐Up®Jr.
This
willcauseblowerbackpressurewhichwillforcewateruptheoverflowpipetobereleasedthroughthebreathervent,
causingthesensorsontheterminalblocktodetectanoverflowofwater.Ventpipingbackpressurecanbecausedbyan
obstruction,icebuild‐up,watertrappedin
areversepitch,excesspipefittingsorpipelength.
High‐WaterAlarm
Afewthingscancausethehigh‐wateralarmvalvecontroltosound:
The leak detection terminal block or floor sensor is wet, repair leak and dry off the top of the Bubble‐Up® Jr
Interactive™.
Vent
line is obstructed, forcing the water up the overflow and triggering the terminal block sensors.Clear
obstruction.
HighwateralarmfloatistriggeredduetooverfillingthemaintankoftheBubble‐Up®JrInteractive™.Thiscanbe
causedbyafailedorstucksolenoid,tangledfloatswitchassembly,
orafailedfloatswitchassembly.Checktosee
thatsolenoidandfloatswitchareworkingproperlyandreplaceifnecessary.
ReplacementParts
ThebackofthismanualshowsthereplacementpartsonaBubble‐Up®JrInteractive™.ManyareshowninFigures6
through14.Figures13and14
showthepartsincludedintheRetrofitKit.Thiskitisuse dtoupgradeaBubble‐Up®JrXP
toaBubble‐Up®JrInteractive™.SeedealerformoreinformationregardingthisRetrofitKit.Herearesomepointsto
keepinmindwhenreplacingparts:
• Beforeremovinganyparts,shut
offthewaterinlettotheBubble‐Up®JrInteractive™.Setthehandlesonthe
bypassvalvetothebypassposition.
• Alwaysunplugallofthepowercordsbeforeworkingontheunit.
• Noticethat,insideeachendofthebluewatertubingthereisastainlesssteel
insertandaplasticferrule.Thisis
animportantpartoftheconnection.Youmayneedtoreplacethisferrulewhenyoureplaceoneofthese
connections.