BubbleUp®JrInteractive™RadonRemovalSystem
15
ThissituationcanbecausedbysimplyusingmorewateroutoftheBubbleUp®Jrthanwhatiscomingin.Comparewater
outletflowwith“currentflow”metercontrolreadingontheBubbleUp®Jrwhilefilling.
Afewinletflowproblemsare;lowyieldwell,wellpump
failure,cloggedplumbingorwaterfiltrationrestrictingwaterflow
fillingtheBubbleUp®Jr.
NowaterfromtheBubbleUp(alarmissounding)
Cause:WaterAlarmValveshutwaterofftoBubbleUp®Jr.
Example:TheBubbleUp®JrInteractiveincludesawateralarmvalvewhichsoundsanalarmand
stopswaterfillingthe
BubbleUpwhenaleakoroverflowconditionisdetected.OncewaterstopsfillingtheBubbleUp®Jr,continuedwateruse
willcausethelowwaterfloatswitchtostoptheBubbleUppumpfromdeliveringwaterflowtothehouse.
Examples:Thealarmconditionsto
causethewateralarmvalvetocloseandstopwaterfromenteringtheBubbleUp®Jr
are; 1‐ the water sensor box detects water on the floor around the BubbleUp® Jr 2‐ the water sensor terminal block
detectswaterontopoftheBubbleUp® Jror3‐thehigh
waterfloatswitchsenseshighwaterinthemaintank.
Theseconditionsarecausedbywaterdetectionduetohighwaterlevels,waterleaks,condensationEtc.
AlsoiftheairventpipingisrestrictedtheBubbleUp®Jrblower cannotfreelyblowtheairoutoftheBubbleUp®Jr.
This
willcauseblowerbackpressurewhichwillforcewateruptheoverflowpipetobereleasedthroughthebreathervent,
causingthesensorsontheterminalblocktodetectanoverflowofwater.Ventpipingbackpressurecanbecausedbyan
obstruction,icebuildup,watertrappedin
areversepitch,excesspipefittingsorpipelength.
HighWaterAlarm
Afewthingscancausethehighwateralarmvalvecontroltosound:
The leak detection terminal block or floor sensor is wet, repair leak and dry off the top of the BubbleUp® Jr
Interactive™.
Vent
line is obstructed, forcing the water up the overflow and triggering the terminal block sensors.Clear
obstruction.
HighwateralarmfloatistriggeredduetooverfillingthemaintankoftheBubbleUp®JrInteractive™.Thiscanbe
causedbyafailedorstucksolenoid,tangledfloatswitchassembly,
orafailedfloatswitchassembly.Checktosee
thatsolenoidandfloatswitchareworkingproperlyandreplaceifnecessary.
ReplacementParts
ThebackofthismanualshowsthereplacementpartsonaBubbleUp®JrInteractive™.ManyareshowninFigures6
through14.Figures13and14
showthepartsincludedintheRetrofitKit.Thiskitisuse dtoupgradeaBubbleUp®JrXP
toaBubbleUp®JrInteractive™.SeedealerformoreinformationregardingthisRetrofitKit.Herearesomepointsto
keepinmindwhenreplacingparts:
Beforeremovinganyparts,shut
offthewaterinlettotheBubbleUp®JrInteractive™.Setthehandlesonthe
bypassvalvetothebypassposition.
Alwaysunplugallofthepowercordsbeforeworkingontheunit.
Noticethat,insideeachendofthebluewatertubingthereisastainlesssteel
insertandaplasticferrule.Thisis
animportantpartoftheconnection.Youmayneedtoreplacethisferrulewhenyoureplaceoneofthese
connections.