35
Line 1 Pulse = SUB n sec VOP
V Gain = 32 x
VOP = 83%
L1 =40 dBRL
Batt
P r e s s
*
7 2 f t
2 2 m
2
1
Line 1 Pulse = SUB nsec VOP
V Gain = 104 x
VOP = 83%
L1 =38 dBRL
Batt
P r e s s
*
5 2 ft
1 6 m
2
1
The three events seen in this section of 750 CATV
hardline are a minor dent, a major dent, and a
questionable splice.
The horizontal zoom and vertical gain keys allow the
operator to view these three crimps more closely.