- 69 -
Green colour: weight value within set threshold values
Red colour: weight value above Max threshold value
PROCEDURE 2entering checkweighing thresholds manually
Press < Checkweighing Thresholds> button,
Window with an on-screen numeric keyboard is displayed, use it to enter Min threshold value,
Press < > button for confirmation,
Window with an on-screen numeric keyboard is displayed, use it to enter Max threshold value,
Press < > button for confirmation,
Home screen of the mode is displayed with entered threshold values.
CAUTION!
Max threshold value has to be greater than Min threshold value.
For thresholds value modification the following buttons are used:
- Min threshold value modification, enter the new value using an on-screen numeric
keyboard, next press <
> button for confirmation. Upon confirmation, home screen of
checkweighing mode is automatically displayed.
- Max threshold value modification, enter the new value using an on-screen numeric
keyboard, next press <
> button for confirmation. Upon confirmation, home screen of
checkweighing mode is automatically displayed.
15. DOSING
< Dosing> is a working mode for performance of sampling process, wherein the sampling takes
as long as it is necessary to obtain pre-defined target weight.