EasyManua.ls Logo

Rain Bird WP 2 - Troubleshooting; Station Does Not Come On; Irrigation Continues After Battery Removal

Rain Bird WP 2
18 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
32
TROUBLESHOOTING
Symptom Possible cause
Station does not come on
Make sure a 9V lautching solenoid is used
Check electric wiring
No run time has been set for the station
Sensor system is preventing irrigation
Start time has not been entered for the
program to which the station is assigned
Water budget for the station’s program is
set to 0%
I remove batteries from the controller but the
irrigation continues
Battery powered controllers operate by
impulses. To stop watering, the electric
valve needs to receive a shutdown
impulse.
Removing batteries prevent the controller
from sending the shutdown impulse.
All manuals and user guides at all-guides.com
all-guides.com

Related product manuals