HV & HVF VALVES
HV/HVF Installation Instructions ........................................................................2
Instruction pour l’installation des vannes HV/HVF ...................................4
Installationsanleitung für die Ventile HV/HVF .............................................6
Istruzioni per l’installazione HV/HVF ................................................................8
Instrucciones para Instalar la HV/HVF ..........................................................10
HV/HVF Installatie Handleiding .......................................................................12
Instruções para Instalar o HV/HVF..................................................................14
Οδηγίες εγκατάστασης HV/HVF ......................................................................16
HV/HVF Kurulum Talimatları .............................................................................18
Инструкции по установке HV/HVF ............................................................. 20
GB
F
D
I
E
NL
P
®
Registered trademark of Rain Bird Corporation.
© 2013 Rain Bird Corporation 11/13
P/N 236308
Rain Bird Corporation
6991 E. Southpoint Road
Tucson, AZ 85756 USA
Phone: (520) 741-6100
Fax: (520) 741-6522
Rain Bird Corporation
970 West Sierra Madre Avenue
Azusa, CA 91702 USA
Phone: (626) 812-3400
Fax: (626) 812-3411
Rain Bird International
1000 W. Sierra Madre Ave
Azusa, CA 91702 USA
Phone: (626) 963-9311
Fax: (626) 852-7343
Rain Bird Technical Services
(800) RAINBIRD (1-800-724-6247)
(U.S. and Canada)
Specification Hotline
800-458-3005 (U.S. and Canada)
The Intelligent Use of Water
www.rainbird.com
Rain Bird Europe SNC
Rain Bird France SNC
900, rue Ampère, B.P. 72000
13792 Aix en Provence Cedex 3
France
Tel: +33 4 42 24 44 61
Fax: +33 4 42 24 24 72
rbe@rainbird.eu
www.rainbird.eu
rbf@rainbird.eu
www.rainbird.fr
Rain Bird Deutschland GmbH
Oberjesinger Str. 53
71083 Herrenberg-Kuppingen
Deutschland
Tel.: +49 07032 99010
Fax: +49 07032 990111
rbd@rainbird.eu
www.rainbird.de
Rain Bird Ibérica S.A.
Polígono Ind. Pinares Llanos
c/Carpinteros, 12, 2°C
28670 Villaviciosa de Odón, Madrid
España
Tel: +34 91 632 48 10
Fax: +34 91 632 46 45
rbib@rainbird.eu
www.rainbird.es
portugal@rainbird.eu
www.rainbird.pt
Rain Bird Sverige AB
Fleningevägen 315
260 35 Ödåkra
Sweden
Tel: +46 42 25 04 80
Fax: +46 42 20 40 65
rbs@rainbird.eu
www.rainbird.se
Rain Bird Turkey
Ístiklal Mahallesi
Alemdağ Caddesk No. 262
34760 Ümraniye, Ístanbul
Türkiye
Tel: +90 216 443 75 23
Fax: +90 216 461 74 52
rbt@rainbird.eu
www.rainbird.com.tr
Rain Bird Mexico S. de R. L de C.V
Calzada Juan Gil
Preciado # 2450, 15A
Parque Ind. Ecopark
Colonia El Tigre CP45100
Zapopan, Jalisco, Mexico
Tel: +52 333 364 4785
Fax: +52 333 364 4787
Rain Bird (Australia) Pty. Ltd
10 Mareno Rd.
TULLAMARINE VIC 3043
Australia
Tel: +61 (0)3 8336 6777
Fax: +61 (0)3 9338 1699
sales@rainbird.com.au
www.rainbird.com.au
Rain Bird Brasil Ltda
Rua Piaui, 740 Marta Helena
Uberlandia, MG 38402020
Brasil
Tel: +55 34 3212 8484
Fax: +55 34 3213 5469
Rain Bird Trading (Shanghai)
Company Limited
Rm 1008, E1
Yuan Chen Xin Bldg 12
Yumin Rd, Chaoyang District
Beijing, 100029 China
Tel: +86 10 8225 1759
Fax: +86 10 8225 1301
www.rainbird.com.cn
Rain Bird Jebel Ali
JAFZA- LOB14- Oce 318
P.O.Box: 261771- Dubai - UAE
Tel: +971 4 8819671
Fax: +971 4 8819672
EL
T

Flow Control models
NPT and BSP threaded models Male by Barb models
Slip by Slip models

Questions and Answers

  • J
    Jeffrey VazquezJul 28, 2025
    What to do if Rain Bird HV Control Unit valve won’t open or slams on/off?
    • D
      Dr. Melissa GoodmanJul 28, 2025
      If your Rain Bird Control Unit valve won't open or slams on and off, start by ensuring your water source is active, the controller has power, and the flow control is open. If issues persist, turn off the water supply, remove the bonnet screws, and inspect the valve body for any obstructions. If the diaphragm filter is missing, replace the diaphragm using kit number 210746-03. You can also try replacing the solenoid with one that is known to be working. If the valve remains unresponsive, consider replacing the solenoid entirely. Finally, check your system's water pressure; if it exceeds 80 psi (5,5 bar), install a pressure regulator before the valve to lower the water pressure.
  • D
    Deborah BartlettAug 3, 2025
    How to fix Rain Bird Control Unit valve that won’t shut off completely?
    • M
      Michael JohnstonAug 4, 2025
      To address a Rain Bird Control Unit valve that won’t completely shut off, causing sprinklers to “weep,” begin by fully tightening the solenoid (a quarter turn beyond hand tight) to ensure a complete valve closure. Also, tighten both the bleed screw and bonnet screws. Use the external bleed screw to flush the valve. If the issue continues, turn off the water supply, unscrew the bonnet screws, and remove the bonnet to access the diaphragm. Clean the diaphragm with clear water, then reinstall it along with the bonnet. If necessary, replace the diaphragm using kit number 210746-03.
  • A
    Allison GarciaAug 9, 2025
    What to do if Rain Bird Control Unit valve won’t shut off completely?
    • C
      cmooreAug 9, 2025
      To address a Rain Bird Control Unit valve that won’t shut off completely, causing sprinklers to 'weep,' start by fully tightening the solenoid (a quarter turn beyond hand tight) to ensure a complete valve shut-off. Also, tighten both the bleed screw and bonnet screws. Flush the valve using the external bleed screw. If the issue persists, turn off the water supply, unscrew the bonnet screws, and remove the bonnet. Remove the diaphragm and clean it thoroughly with clear water before reinstalling it along with the bonnet. If necessary, replace the diaphragm. Additionally, turn off the water, remove the solenoid, and clean any dirt or grit from the solenoid bowl before replacing the solenoid. Finally, turn the water back on and check for any remaining weeping.
  • D
    David WardAug 21, 2025
    How to fix Rain Bird Control Unit valve slamming on/off (water hammer)?
    • I
      igreeneAug 21, 2025
      If your Rain Bird Control Unit valve is slamming on or off, causing water hammer, check the system's water pressure. If it exceeds 80 psi, install a pressure regulator before the valve to reduce it. For Flow Control models, turn on the zone using the solenoid, then decrease the flow control until a drop in system performance occurs. Finally, slightly increase the flow control only until the system performance is restored.
  • U
    ulamNov 14, 2025
    Why Rain Bird Control Unit valve won't open?
    • J
      Jennifer GarrettNov 14, 2025
      If your Rain Bird Control Unit valve won't open, begin by verifying the water source, controller power, and flow control are all active and open. Then, turn off the water supply and unscrew the bonnet screws to remove the bonnet, inspecting the valve body for any debris. If the diaphragm filter is missing, replace the diaphragm. Next, turn off the water again, remove the solenoid, and carefully insert a small, stiff wire into the hole at the center of the solenoid bowl, pushing it into the valve outlet, being careful not to damage the top lip of the hole. Remove the wire and replace the solenoid. If the valve remains closed, replace the original solenoid. Finally, manually open the valve using the External Manual Bleed Screw to release any trapped air above the diaphragm, then close it usi...

Summary

Installation and Operation

Before Installation Steps

Ensures proper water supply, pressure, flow, and system flushing before valve installation.

Connecting Valve Components

Guides on connecting adapters, pipes, and wires to the valve for proper function.

Manual Valve Operation

Instructions for manually opening, closing, and adjusting the valve's flow.

Valve Operating Parameters

Troubleshooting Valve Issues

Valve Not Shutting Off

Diagnoses and resolves issues with the valve not shutting off completely or weeping.

Valve Not Opening

Troubleshoots why the valve fails to open, checking for obstructions or solenoid issues.

Water Hammer Issues

Addresses valve slamming on/off by checking pressure and flow control settings.

Rain Bird HV Series Specifications

General IconGeneral
BrandRain Bird
ModelHV Series
CategoryControl Unit
LanguageEnglish

Related product manuals