The TC series is tested and certified by the WQA to NSF/ANSI 44 for the specific
performance claims as verified and substantiated by test data. See the performance
data sheet for specific reduction claims.
Part No.: 16618
Rev: H 05/16
The TC series is tested and certified by the WQA to NSF/ANSI 372 for “lead
free”Compliance.
The TC series is tested and certified by the WQA to CSA B483.1 Standard.
Rainsoft Division of Aquion, Inc
101 S. Gary Ave
Roselle, Illinois 60172
1.847.437.9400 or 1.800.860.7638
www.rainsoft.com
TC CONDITIONER SERIES
WATER TREATMENT SYSTEM

Questions and Answers

  • P
    Patricia EverettAug 10, 2025
    What to do if my Rain Soft TC 75 V has poor water quality?
    • S
      Stacy CastilloAug 10, 2025
      If you are experiencing poor water quality with your Rain Soft Water System, there are a few potential causes. First, the raw water source might have changed, requiring a new water analysis from your RainSoft dealer. Second, check if the bypass valve is closed; if not, close it. Finally, ensure the power supply is properly connected.
  • K
    Karen SimmonsAug 17, 2025
    How to troubleshoot loss of water pressure in Rain Soft Water System?
    • M
      Michael JamesAug 17, 2025
      If you're experiencing a loss of water pressure with your Rain Soft Water System, the first step is to bypass the system. If the problem persists after bypassing, it is not related to a RainSoft product; check your water distribution system. If bypassing resolves the issue, contact your RainSoft Dealer for service. Another potential cause is low pressure to the unit.
  • B
    Blake TurnerAug 25, 2025
    How to fix Rain Soft TC 75 V that regenerates at the wrong time?
    • A
      Ashley YoderAug 25, 2025
      If your Rain Soft Water System regenerates at the wrong time, it is possible that the computer is not set properly. Reset the time of day/hour of regeneration.
  • T
    Teresa DuncanSep 1, 2025
    What causes constant flow to the drain in Rain Soft TC 75 V?
    • J
      Jacob DuranSep 1, 2025
      Constant flow to the drain in your Rain Soft Water System can be caused by foreign material in the valve, which requires cleaning by your RainSoft Dealer. Another possible cause is excessive water pressure; in this case, install a pressure regulator.

Summary

Operational Specifications

Maintenance Requirements

Installation Instructions

Safety Precautions

Essential safety measures to follow during system installation.

Install the Valve Head

Steps for correctly attaching the control valve to the tank.

Turn Off the Water and Drain the Plumbing

How to safely shut off water and drain pipes before installation.

Install the Pipe Connector (Yoke) to the Bypass Valve

Steps for connecting the yoke and bypass valve to the plumbing.

Set the Bypass Valve to Bypass

How to position the bypass valve handles for initial setup.

System Start Up

Turn on the Water and Check for Leaks

Procedure for restoring water supply and verifying no leaks occur.

Flush the Remaining Debris from the System

Steps to flush the system and plumbing lines after installation.

Open the Bypass Valve

How to switch the bypass valve from bypass to service position.

Add Salt and Program the Computer

Guidance on adding salt and configuring system settings.

Sanitize the Conditioner

Method for sanitizing the water conditioner unit.

Customer Settings

Manual regeneration

Instructions for initiating a regeneration cycle manually.

Installers Only Section

How to Calculate the Regeneration Schedule

Troubleshooting Guide

Limited Lifetime Warranty

Rain Soft TC 75 V Specifications

General IconGeneral
BrandRain Soft
ModelTC 75 V
CategoryWater System
LanguageEnglish