36
4.5 International settings
Selection of the measures to be used for pressure
and temperature from ba to P.S.I. and from C to
°F°.
4.4 Check distribution time
Possibility of activating one of the following func-
tions:
- Function “0” – Function not enabled
- Function “1–the distribution time for each coffee
will be displayed at the end of the distribution of a
t12 time.
- Function “2–During the dose programming pha-
se, in self-learning or at the rst distribution after
varying a dose, the time of each distribution is
stored. This time is compared during the following
distributions and will be displayed for a t12 time at
the end of the distribution:
- O.K.if the distribution time falls within a tole-
rance of +/- 3 sec
- on the contrary if the difference in seconds is
higher than the tolerance, the non-corrected data
will be displayed (ex. “+5”)
4.6 Cleaning
This submenu gives the possibility of setting all
modes concerning the washing of coffee groups, and
washing counters.
If the automatic operation mode is set, at the xed
time, a message on the display will remind to start
the washing cycles.