Command reference
R&S
®
ZNA
1356User Manual 1178.6462.02 ─ 20
REV
Reverse coupler configuration
SRC
Source monitor access
Usage: Setting only
Options: R&S ZNAxx-B16
Manual operation: See "Receiver Input" on page 622
[SENSe<Ch>:]PATH<Pt>:IFINpath
<Direct IF Access InPath>
Selects the input paths of the Direct IF Access Input / Output connectors IF Reference
<Pt> and IF Meas <Pt> in channel <Ch>.
This setting only takes effect if [SENSe<Ch>:]PATH<Pt>:IFSWitch is set to IN.
Suffix:
<Ch>
.
Channel number
<Pt> Port number
Setting parameters:
<Direct IF Access
InPath>
DIRect | LP_60m | BP_279m
DIRect
Frequency range 5kHz to 1 GHz
LP_60m
Low pass, frequency range 5 kHz to 60 MHz
BP_279m
Band pass, frequency range 260 MHz to 290 MHz
Usage: Setting only
Options: R&S ZNA-B26
Manual operation: See "Rear Input Path" on page 623
[SENSe<Ch>:]PATH<Pt>:IFOutauto <Boolean>
Defines how the outgoing frequencies at IF Reference <Pt> and IF Meas <Pt> are
determined in channel <Ch>.
This setting only takes effect if [SENSe<Ch>:]PATH<Pt>:IFSWitch is set to OUT.
Suffix:
<Ch>
.
Channel number
<Pt> Port number
Setting parameters:
<Boolean> OFF
The frequencies are set manually.
Use [SENSe<Ch>:]PATH<Pt>:IFRequency to define a suita-
ble frequency conversion formula.
SCPI command reference