Command reference
R&S
®
ZNA
1358User Manual 1178.6462.02 ─ 20
FB
The IF frequency at IF Reference <Pt> and IF Meas <Pt>
sweeps with the channel base frequency.
CW
Fixed IF frequency at IF Reference <Pt> and IF Meas <Pt>.
*RST: SWEep
Usage: Setting only
Options: R&S ZNA-B26
Manual operation: See "Rear IF Frequency" on page 623
[SENSe<Ch>:]PATH<Pt>:IFSWitch <Selection of IF Switch on Ref and Meas path>
Defines if and how the Direct IF Access Input / Output ports IF Reference <Pt> and IF
Meas <Pt> are used in channel <Ch>.
Suffix:
<Ch>
.
Channel number
<Pt> Port number
Setting parameters:
<Selection of IF
Switch on Ref and
Meas path>
OFF | IN | OUT
OFF
The ports are unused.
IN
The ports are for IF input (but not for IF output).
Note that direct generator/receiver access cannot be used in this
case.
OUT
The ports are for IF output (but not for IF input).
Usage: Setting only
Options: R&S ZNA-B26
Manual operation: See "Rear Out" on page 622
[SENSe<Ch>:]PATH<Pt>:MEASurement:DIRectaccess?
[SENSe<Ch>:]PATH<Pt>:REFerence:DIRectaccess?
Queries the direct generator/receiver access path.
To define the direct generator/receiver access path, use [SENSe<Ch>:]PATH<Pt>:
DIRectaccess.
Note that direct generator/receiver access and direct IF input cannot be used at the
same time. Direct generator/receiver access is only used if [SENSe<Ch>:
]PATH<Pt>:IFSWitch is set to OFF or OUT.