<TransCoeff> Transmission coefficient
Range: -300 dB to +200 dB
*RST: n/a
Default unit: dB
Example: See SOURce<Ch>:POWer<PhyPt>:CORRection:
TCOefficient:CALibration
Manual operation: See "Frequency / Transm. Coefficients: Insert, Delete, Delete
All" on page 578
SOURce:POWer... (contd.)
The SOURce:POWer... commands define the power of the internal signal source.
SOURce:POWer:GENerator:SDELay.............................................................................1462
SOURce:POWer:REDuce:SDELay................................................................................ 1463
SOURce:POWer:SWEepend:MODE.............................................................................. 1463
SOURce:POWer:SWEepend:SDELay............................................................................1463
SOURce<Ch>:POWer<PhyPt>[:LEVel][:IMMediate][:AMPLitude]...................................... 1464
SOURce<Ch>:POWer<PhyPt>[:LEVel][:IMMediate]:OFFSet............................................ 1464
SOURce<Ch>:POWer<PhyPt>[:LEVel][:IMMediate]:SLOPe............................................. 1465
SOURce<Ch>:POWer<PhyPt>:ATTenuation...................................................................1466
SOURce<Ch>:POWer<PhyPt>:CORRection:GENerator<Gen>:LEVel:OFFSet...................1466
SOURce<Ch>:POWer<PhyPt>:CORRection:LEVel:OFFSet............................................. 1467
SOURce<Ch>:POWer<Pt>:EATTenuation...................................................................... 1468
SOURce<Ch>:POWer<Pt>:EATTenuation:MODE............................................................1468
SOURce<Ch>:POWer<PhyPt>:GENerator<Gen>:OFFSet............................................... 1468
SOURce<Ch>:POWer<PhyPt>:GENerator<Gen>:PERManent[:STATe]............................. 1469
SOURce<Ch>:POWer<PhyPt>:GENerator<Gen>:STATe................................................. 1470
SOURce<Ch>:POWer<PhyPt>:GENerator<Gen>:LLIMit[:STATe]......................................1470
SOURce<Ch>:POWer<PhyPt>:GENerator<Gen>:LLIMit:VALue....................................... 1471
SOURce<Ch>:POWer<PhyPt>[:LEVel][:IMMediate]:LLIMit[:STATe]................................... 1471
SOURce<Ch>:POWer<PhyPt>[:LEVel][:IMMediate]:LLIMit:VALue.....................................1472
SOURce<Ch>:POWer<PhyPt>:PERManent[:STATe]....................................................... 1472
SOURce<Ch>:POWer<PhyPt>:REDuce[:STATe].............................................................1473
SOURce<Ch>:POWer<PhyPt>:STATe............................................................................1473
SOURce<Ch>:POWer<PhyPt>:STARt........................................................................... 1474
SOURce<Ch>:POWer<PhyPt>:STOP............................................................................1474
SOURce:POWer:GENerator:SDELay <SettlingDelay>
If external generators are used in the measurement, this defines the minimum settling
delay before the external generators are considered to be ready, i.e. the time between
setting the generator to the requested frequency and power and continuing with the
measurement.