GUI reference
R&S
®
ZNA
701User Manual 1178.6462.02 ─ 20
CALCulate:FMODel:DELT<Ph_pt>:FREQuencies:DEFault:COUNt?
CALCulate:FMODel:DELT<Ph_pt>:FREQuencies:USER?
CALCulate:FMODel:DELT<Ph_pt>:FREQuencies:USER:COUNt?
CALCulate:FMODel:DELT<Ph_pt>:FREQuencies:USER:ADD
CALCulate:FMODel:DELT<Ph_pt>:FREQuencies:USER:DELete
CALCulate:FMODel:DELT<Ph_pt>:FREQuencies:USER:DELete:ALL
Sweep Control
The Delta-L measurement channel can either "Use Defaults" (10 MHz step size and
1 kHz IF bandwidth), or the "Current Sweep" settings (see "Freq Step Size"
on page 489, and "Bandwidth" on page 485).
For "Dynamic Bw at Low Frequencies", see Dynamic Bw at Low Frequencies.
Remote command:
CALCulate:FMODel:DELT<Ph_pt>:SWEep:CONTrol
CALCulate:FMODel:DELT<Ph_pt>:SWEep:CONTrol:BWIDth[:RESolution]:
DREDuction
CALCulate:FMODel:DELT<Ph_pt>:SWEep:CONTrol:STEP?
CALCulate:FMODel:DELT<Ph_pt>:SWEep:CONTrol:IFBW?
Sweep Frequency
Defines the sweep range of the Delta-L channel. The entered "Minimum" and "Maxi-
mum" values are set as start and stop frequency when the Delta-L settings are applied
using "OK". Furthermore, the VNA collects data for the LPI computation a the "Mini-
mum" and "Maximum" frequencies (in addition to the other specified "Frequencies"
on page 700).
The default "Minimum" is the standard Delta-L start frequency of 10 MHz. The default
"Maximum" is 20 GHz. Buttons are available to set "Maximum" to the standard Delta-L
stop frequencies of 20 GHz and 40 GHz (if within the instrument's frequency range),
and to the instrument's maximum frequency.
If you set the "Minimum" or "Maximum" to a non-standard value, a popup indicates that
the Delta-L measurement possibly does not provide accurate results.
Remote command:
CALCulate:FMODel:DELT<Ph_pt>:SWEep:FREQuency:MINimum on page 938
CALCulate:FMODel:DELT<Ph_pt>:SWEep:FREQuency:MAXimum on page 938
Trace
On OK, the VNA deletes the existing traces and sets up the traces whose measure-
ment is required for the selected Delta-L Method.
If "Use Recommended Trace Configuration" is checked, then each of the new
traces is displayed in a separate diagram. Otherwise, the VNA places all traces in a
single diagram.
If the Time domain analysis option R&S ZNA-K2 is installed, "Show TDR Impedan-
ces" adds the TDR-based converted impedance traces to the recommended trace
configuration.
Offset Embed softtool