15. Technical Data
THIS COOKER IS CATEGORY: CatII
2H3+.
It is supplied set for group H natural gas. A conversion kit from NG to LP is available for the cooker.
INSTALLER: Please leave these instructions with the User.
DATA BADGE LOCATION: Cooker back, serial number repeater badge below oven door opening.
COUNTRY OF DESTINATION: GB, IE.
Connections
Gas (Rp ½ at rear right-hand side) Electric
Natural Gas
20 mbar
230/400 V 50 HzButane 29 mbar
Propane 37 mbar
Dimensions
Model Elise 90 Dual Fuel
Overall height minimum 937 mm
maximum 962 mm
Overall width 900 mm
Overall depth
598 mm excluding handles, 650 mm including handles
Minimum height above the hotplate 650 mm
Refer to ‘Positioning the Cooker’.
Ratings
Hotplate Bypass Screw*
Natural Gas 20mb LP Gas
Injector Injector
Wok burner 57
3.5 kW
internal 78
3.5 kW (246 g/h)
internal 53
external 126 external 82
Large burner 40
3.0 kW 134 3.0 kW (210 g/h) 87
Medium burner 32
1.7 kW 109 1.7 kW (119 g/h) 68
Small burner 28
1.0 kW 75 1.0 kW (70 g/h) 51
* The valves in this cooker are tted with adjustable bypass screws. The cooker is supplied with the bypass screws set for
Natural gas. For LPG conversion the bypass screws must be screwed all the way down.
Hotplate energy saving tips Oven energy saving tips
Use cookware with a at base. Cook meals together, if possible.
Use the correct size cookware. Keep the pre-heating time short.
Use cookware with a lid. Do not lengthen cooking time.
Minimise the amount of liquid or fat. Do not open the oven door during the cooking period.
When liquid starts boiling, reduce the setting. Do not forget to turn the appliance o at the end of cooking.
Consumption is based on G30.